【DO!BOOK・ページリンク】 fi-04 121 / 228 10秒後にBOOKのページに移動します |
|
No. SS2-MTG300-0100 Azbil Corporation - 4 - Lightning protection 12 kV, 1000A Equipped with the lightning arrester in the power source and external output terminals. Power failure An EEPROM retains data record of totalized value when pulse output is used (retention period approximately 10 years). Power supply 15.6 to 42V DC (without communication) 21.05 to 42V DC (with communication) Current capacity: 24mA min. In case of current capacity is 22mA, the voltage must be 15.6V minimum. Size Wafer style 25, 40, 50, 65, 80, 100 mm (1, 1., 2, 2., 3, 4 inches) Flange style 2.5, 5 mm (0.1, 0.2 inch) (Model MTG18A only) 10, 15, 25, 40, 50, 65, 80, 100, 150, 200 mm (3/8, 1/2, 1, 1., 2, 2., 3, 4, 6, 8 inches) Flange rating ANSI150, ANSI300, DIN PN10, DIN PN16, DIN PN25, JIS10K, JIS20K, JIS30K Reference flange standard JIS; JIS B2210 (1984) ANSI; ANSI B16.5 (1988) Ambient temperature limits -20 to 60°C (-4 to 140°F) Ambient humidity limits 10 to 90% RH Vibration effect Integral style: 4.9m/s2(0.5G) max. Remote style converter: 19.6m/s2(2G) max. Remote style detector: 19.6m/s2(2G) max. Temperature range and pressure range of process fluid Refer to the following. Size: 2.5 to 10 mm (0.1 to 3/8 inch) Size: 15 to 200 mm (1/2 to 8 inch) Measurable electrical conductivity 10 ..S/cm or greater 50 ..S/cm or greater (10 mm (3/8 inch), 15 mm (1/2 inch) for remote type) Measurement flow range Size Maximum flow velocity range is 0 to 0.3 m/s (0 to 0.98 ft/s) Maximum flow velocity range is 0 to 10 m/s (0 to 32.8 ft/s) Conversion Minimum range Maximum range factor K mm inches m3/h GPM m3/h GPM 2.5 0.1 0 to 0.00531 0 to 0.02335 0 to 0.1767 0 to 0.778 56.59 5 0.2 0 to 0.02121 0 to 0.09337 0 to 0.7068 0 to 3.112 14.15 10 3/8 0 to 0.08483 0 to 0.3735 0 to 2.827 0 to 12.44 3.537 15 1/2 0 to 0.1909 0 to 0.8404 0 to 6.361 0 to 28.00 1.572 25 1 0 to 0.5302 0 to 2.335 0 to 17.67 0 to 77.80 0.5659 40 1. 0 to 1.358 0 to 5.976 0 to 45.23 0 to 199.1 0.2210 50 2 0 to 2.121 0 to 9.337 0 to 70.68 0 to 311.2 0.1415 65 2. 0 to 3.584 0 to 15.78 0 to 119.4 0 to 525.9 0.08371 80 3 0 to 5.429 0 to 23.91 0 to 180.9 0 to 796.7 0.05526 100 4 0 to 8.483 0 to 37.35 0 to 282.7 0 to 1244 0.03537 150 6 0 to 19.09 0 to 84.04 0 to 636.1 0 to 2800 0.01572 200 8 0 to 33.93 0 to 149.4 0 to 1130 0 to 4979 0.008842 Velocity V (m/s) = K × Q K= Conversion factor = 1/3600 × 4/(..D2) × 10002, D = Size (mm), Q = Flow rate (m3/h) 2.94 MPa (426 psi) 1.96 MPa (284 psi) -0.098 MPa (-14.2 psi) -20 C (-4 F) 80 C (176 F) 100 C (212 F) 2.94 MPa (426 psi) -0.098 MPa (-14.2 psi) 0.98 MPa (142 psi) -20 C (-4 F) 80 C (176 F) 120 C (248 F) 130 C (266 F) |