【DO!BOOK・ページリンク】 fi-04 139 / 228 10秒後にBOOKのページに移動します |
|
No. SS2-MTG300-0300 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS Enclosure rating JIS C 0920 watertight model NEMA TYPE 4X, IEC IP67 Hazardous Areas certifications TIIS Explosion-protected apparatus Ex de [ia] II C T4 Certificate number Output signal Analog output 4 to 20mA DC Digital output DE Analog or Digital output is selectable. Pulse output Open collector output (30 V DC, 100mA max.) Pulse frequency: 0.0001 to 200 Hz Pulse width: 1 ms to 1 s LOW value: 2.7V (10mA) (Refer to the blow drawing.) Contact output Open collector output (30 V DC, 100mA max.) Pulse or contact output is selectable Communication protocol SFC communication and HARTR communication HARTR communication . Multidrop mode: current fixed at 12mA. Optional Burst mode is not available. Load resistance characteristic of communication External power supply 21.05 to 42 V DC for communication. Note) The load resistance of 250 .. or more is necessary for communications of SFC and the HARTR communicator. Flow unit Volume flow: m3, L, cm3, G (gallon), mG, kG, B (barrel), IG (imperial gallon), mIG, kIG Mass flow: t, kg, g, lb Time: d, h, m, s Display Display: LCD Main display: 7-segment, 8 digits Sub display: 16 digits, 2 lines Display contents: Demonstrates three values simultaneously Percentage flow rate, Actual flow rate, Totalized value Data setting Operation by four key switches Damping Adjustable between 0.5 and 199.9 seconds. Low flow cutoff Adjustable between 0 and 10% of setting range. Below selected value, output is driven to the zero flow rate signal level. Dropout Adjustable between 0 and 10% of setting range. Below selected value, pulse output is cut. Line size (mm) Flange (Pipe material: SCS14) Flange (Pipe material: SUS304) Wafer (Pipe material: SCS14) Wafer (Pipe material: SUS304) 2.5 TC19022 - - - 5 TC19022 - - - 10 TC19022 - - - 15 TC19022 - - - 25 - TC19028 TC19023 TC19028 40 - TC19029 TC19024 TC19029 50 - TC19031 TC19025 TC19031 65 - TC19030 TC19026 TC19030 80 - TC19032 TC19027 TC19032 100 - TC19020 TC19021 TC19020 150 - TC19033 - - 200 - TC19034 - - HIGH 2.7V 0V LOW R= Load resistance (W) Power supply (V DC ) 0.0218 V-15.6 1 21.05 < V< 30 R= 0.02383 V-14.25 2 30 |