【DO!BOOK・ページリンク】 fi-04 191 / 228 10秒後にBOOKのページに移動します |
|
SS2-MVC300-0100 Azbil Corporation - 4 - SPECIFICATIONS Basic specifications Process fluid Steam only (saturated steam) Measurement range and accuracy [Flow rate] Measurable range See Table 1 through 4 on Page11. Accuracy Standard specification: ±3% rdg High-accuracy specification: ±2% rdg Range of guaranteed accuracy [Pressure (static pressure)] Measurable range 0.101 to 3.5 MPa abs* * This is output range of analog output * This is not an operating pressure limit. Accuracy Shown below * Since the absolute pressure sensor is used for the process pressure measurement, the gauge pressure is set as 0.101 MPa abs. [Temperature] Measurable range 0 to 300°C * * This is output range of analog output * This is not an operating temperature limit. Accuracy Accuracy is not specified because the temperature output is calculated from the steam table. Repeatability ±0.5% rdg of flow rate output Fluid pressure Rated pressure of a selected process connection Ambient temperature and steam temperature: Ambient humidity 10 to 90% RH (no condensation) Power source voltage 24 VDC (16.7 to 45 VDC) Pressure loss MVC30A: Ploss = MVC31A: Ploss = Ploss: Pressure loss when the flow rate is Q (kg/h or m3/h) Q: Flow rate (kg/h or m3/h) Qmax: Maximum flow rate in the range of guaranteed accuracy. (kg/h or m3/h) (see table 1 through 4) Grounding Grounding resistance to be less than 100 .. Installation Integral type Structure specifications Material [Measuring pipe section] Measuring pipe body SCS14A, SUS304 (for 150mm only) Support bridge SUS304 (for 150mm only) Packing Graphite Connection Wafer type Flange bore diameter 25mm, 40mm, 50mm, 80mm, 100mm, 150mm Process pressure PP MPaG Range of guaranteed accuracy 0.3 < PP .. 2.0 Up to one tenth of maximum flow limit 0.1 < PP .. 0.3 Up to one eighth of maximum flow limit 0 .. PP .. 0.1 Up to one fifth of maximum flow limit Process pressure PP MPaG Accuracy 0.35 < PP .. 2.0 ±0.3%FS 0.17 .. PP .. 0.35 ± (0.025 + 0.275 .. 0.35 )%FS PP ---------- 0 20 40 60 -20 100 150 200 250 -15 65 190 215 (215,30) (215,-15) (190,65) (200,50) Steam temperature (「ェC) Waterproof specification Explosion-proof specification Ambient temperature (「ェC) 50 Q Qmax .. --------------- .. .. .. .. 2 40 Q Qmax .. --------------- .. .. .. .. 2 |