【DO!BOOK・ページリンク】 fi-04 193 / 228 10秒後にBOOKのページに移動します |
|
SS2-MVC300-0100 Azbil Corporation - 6 - [LCD display output] [LCD display unit] Output in case of abnormality Analog output The burnout function is provided; output is moves to Hi or Lo limit. Otherwise, output can be selected without burnout processing. Burnout current Hi/Lo=20.8 mA to 3.8 mA DC Pulse output If burnout occurs, pulse output stops (not counted). Otherwise, pulse output can be selected from hold (from the counts that are held before the occurrence of abnormality). If power failure occurs Data retention Totalized flow rate values are recorded and retained in EEPROM in power OFF. Communication functions Communicator Field communication software CommStaff Model CFS100 Communication conditions See Figure 10 "Supply voltage and load resistance values". Self-diagnosis: Self-diagnosis functions are provided to detect malfunctioning of EEPROM, CPU or temperature sensors, as well as equipment temperature abnormality. Other specifications Test report* A test report in our company's format is issued. * STEAMcube is a piece of equipment comprising two components: the eTube for generating differential pressure and the multivariable differential pressure transmitter. For differential pressure type flow meters, test data obtained by placing them in the flow of liquid or fluid are usually available. For STEAMcube, however, such test data is not available. Cable gland (one or two) Cable gland required for the Flameproof structure is packaged with the flow meter shipment. Waterproof gland (one or two) Waterproof gland (not explosion-proof) is packaged with the flow meter shipment. Signal cables to be used Signal cables* CVV, CEV, CEE, CVVS, CEVS, CEES * Use a cable with the specific heatproof temperature rating suited for the location where it is used. Display Displayed information Number of digits Character height Main display Instantaneous flow rate 4.5 digits One digit below the decimal point About 6 mm Totalized flow rate 6 digits Sub display Pressure and temperature 4.5 digits One digit below the decimal point About 4 mm Instantaneous flow rate 4.5 digits One digit below the decimal point Totalized flow rate 6 digits Totalized flow rate Instantaneous flow rate Temperature Process pressure t t/day t/h t/min kg kg/day kg/h kg/min °C MPa m3 m3/day m3/h m3/min |