【DO!BOOK・ページリンク】 fi-04 212 / 228 10秒後にBOOKのページに移動します |
|
Azbil Corporation SS2-MVC320-0100 - 5 - Flange specifications JIS 10K and 20K, ANSI 150 and 300, JPI 150 and 300 Flange surface RF (not serrated) [Transmitter body] Meter body SUS316 Diaphragm SUS316L Body cover SCS14 Packing PTFE (polytetrafluoroethylene) and SUS316 Capillary tube SUS316 SWS body cover: SCS14 Diaphragm base: SUS316 Diaphragm: SUS316L Transmitter case Aluminum alloy Transmitter O-ring Chloroprene rubber Fastening bolts and nuts SNB7 or SUS304 Paint Standard (acrylic baked finish) Paint color (Transmitter case) Light beige (Munsell 4Y7.2/1.3) (Transmitter cover) Dark beige (Munsell 10YR4.7/0.5) Protection level JIS C0920 watertight type IEC IP67, NEMA3 and 4X Flameproof structure TIIS Ex d IIB+H2 T4-X Electrical conduit G1/2 (female) .. 2 positions Specifications of the signal conversion section Output signal Analog *1 output, pulse *1 output, (analog and pulse outputs can be used simultaneously) Selection of flow rate output* One flow rate output must be selected from the following three outputs. F specification: Open collector pulse (totalized flow rate) + analog (instantaneous flow rate) P specification: Open collector pulse (totalized flow rate) + analog (saturation pressure) T specification: Open collector pulse (totalized flow rate) + analog (saturation temperature) * Flow rate output is dummy mass flow rate output. It is used to calculate the steam density and the steam saturation temperature measured based on pipe pressure values by referring to the steam table built into STEAMcube and to correct steam density values, on the assumption that the fluid to be measured is saturated steam. [Analog output] Output format Selected flow rate output is output using 4 to 20 mA DC. Damping time constant(63% response) To be selected from 0, 2, 4, 8, 16 and 32 seconds To be selected from instantaneous flow rate, saturation pressure and saturation temperature Dead time 0.4 seconds Response time About 1.5 seconds if the capillary length is 2 m About 2 seconds if it is 3 m About 4 seconds if it is 5 m About 5 seconds if it is 7 m About 6 seconds if it is 9 m (if ambient temperature is 25°C) [Pulse output] Output format Open collector pulse Contact capacity 30 VDC, 50 mA (maximum) Residual voltage at output ON 2.6V max. Leakage current at output OFF 0.19mA max. Frequency 0.006 to 200 Hz 4 18 |