【DO!BOOK・ページリンク】 fi-04 28 / 228 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-MGG200-0100 - 3 - Measurement flow range Refer to the minimum/maximum set ranges shown in the table below Flow conversion Velocity V(m/s) = K × Q K = Flow conversion factor = Q = Flow rate (m3/h) Temperature range and pressure range of process fluid Size Minimum flow velocity range is 0 to 0.1 m/s (0 to 0.33 ft/s) Maximum flow velocity range is 0 to 10 m/s (0 to 32.8 ft/s) Conversion Minimum range Maximum range factor K mm inch m3/h GPM m3/h GPM 2.5 0.1 0 to 0.001768 0 to 0.007782 0 to 0.1767 0 to 0.7781 56.59 5 0.2 0 to 0.007069 0 to 0.03113 0 to 0.7068 0 to 3.112 14.15 10 3/8 0 to 0.02828 0 to 0.1246 0 to 2.827 0 to 12.45 3.537 15 1/2 0 to 0.06362 0 to 0.2802 0 to 6.361 0 to 28.01 1.572 25 1 0 to 0.1768 0 to 0.7782 0 to 17.67 0 to 77.81 0.5659 40 1. 0 to 0.4524 0 to 1.993 0 to 45.23 0 to 199.2 0.2210 50 2 0 to 0.7069 0 to 3.113 0 to 70.68 0 to 311.2 0.1415 65 2. 0 to 1.195 0 to 5.261 0 to 119.4 0 to 526.0 0.08371 80 3 0 to 1.810 0 to 7.969 0 to 180.9 0 to 796.8 0.05526 100 4 0 to 2.828 0 to 12.46 0 to 282.7 0 to 1245 0.03537 125 5 0 to 4.418 0 to 19.46 0 to 441.7 0 to 1945 0.02264 150 6 0 to 6.362 0 to 28.02 0 to636.1 0 to 2801 0.01572 200 8 0 to 11.31 0 to 49.81 0 to 1130 0 to 4980 0.008842 250 10 0 to 17.68 0 to 77.82 0 to 1767 0 to 7781 0.005659 300 12 0 to 25.45 0 to 112.1 0 to 2544 0 to 11205 0.003930 350 14 0 to 34.64 0 to 152.6 0 to 3463 0 to 15251 0.002887 400 16 0 to 45.24 0 to 199.3 0 to 4523 0 to 19920 0.002210 450 18 0 to 57.26 0 to 252.2 0 to 5725 0 to 25211 0.001747 500 20 0 to 70.69 0 to 311.3 0 to 7068 0 to 31125 0.001415 600 24 0 to 101.8 0 to 448.3 0 to 10178 0 to 44820 0.0009824 700 28 0 to 138.6 0 to 610.1 0 to 13854 0 to 61005 0.0007218 800 32 0 to 181.0 0 to 796.9 0 to 18095 0 to 79680 0.0005526 900 36 0 to 229.1 0 to 1009 0 to 22902 0 to 100846 0.0004366 1000 40 0 to 282.8 0 to 1246 0 to 28274 0 to 124501 0.0003537 1100 44 0 to 342.2 0 to 1507 0 to 34211 0 to 150646 0.0002923 Note: The maximum measurable process fluid temperature of the submersible model MGG19 is 120°C (248°F) 1 3600 ----------- 4 πD2 × ---------- Size 15 to 200 mm (1/2 to 8 inches) Size 2.5 to 10 mm (0.1 to 3/8 inch) 2.94 MPa (426 psi) 1.96 MPa (284 psi) -0.098 MPa (-14.2 psi) 2.94 MPa (426 psi) -0.098 MPa (-14.2 psi) -40 (-40) 80 (176) 100 C (212 F) 0.98 MPa (142 psi) -40 (-40) 50 (122) 80 (176) 120 (248) 160 C (320 F) Size 250 to 1100 mm (10 to 44 inches) 1.96 MPa (284 psi) -0.098 MPa (-14.2 psi) 0.98 MPa (142 psi) -40 (-40) -10 (14) 70 (158) 100 (212) 120 C (248 F) Chloroprene rubber and PFA / ETFE lining Polyurethane rubber and PFA / ETFE lining PFA/ETFE lining PFA lining (Remote model only) PFA lining Special products 4 3 |