No. SS2-MGG200-0100 Azbil Corporation - 4 - Ambient temperature limits -25 to +60‹C (-13 to +140‹F) (integral model) -30 to +80‹C (-22 to +176‹F) (remote model, PFA lining) 30 to +60‹C (-22 to +140‹F) (remote model, polyurethane rubber lining/chloroprene rubber lining) Ambient humidity limits 5 to 100 % RH Measurable electrical conductivity Combined with model MGG14C converter 3 ƒÊS/cm or more Vibration effect Integral style: 4.9 m/s2(0.5 G) max. Remote style converter: 4.9 m/s2(0.5 G) max. Remote style detector: 19.6 m/s2(2 G) max. Optional specifications Test report Calibration certificate, withstand voltage test, insulation resistant, hydrostatic pressure test, physical inspection are included. Traceability certificate The following three documents are included. . Traceability System Chart . Traceability Certificate . Test Report Material certificate Material certificate for electrode/grounding ring Gasket for plastic piping When the detector is being mounted on plastic pipe, attach this gasket between the lining and the grounding ring, and between the grounding ring and the plastic pipe flange. Attaching the tag number to the terminal box Stamp the tag with the specified number and attach to the terminal box. The maximum number of characters of the tag number is 8. Attaching the tag number to the neck section Stamp the tag with the specified number and attach to the neck section of the detector with stainless wire. The maximum number of characters of the tag number is 16. PERFORMANCE SPECIFICATIONS Accuracy (in combination with the model MGG14C converter) Vs = Velocity of setting range Vs = Velocity of setting range *)High accuracy calibration is available for sizes of 40 to 350mm (1. to 14 inches). Reference Conditions for high accuracy calibration: . Fluid:Tap water . Fluid temperature:15 to 30‹C . Ambient temperature:15 to 30‹C . Ambient humidity:30 to 70 % . Lengh of straight pipe: Upstream>20~DN Downstream>5~DN (DN:Pipe diamter nominal) . Properly grounded . Properly centered Accuracy is guaranteed by the totalized flow volume under the condition of continuous flow measurement for 30 seconds or longer. Vs (m/s) Velocity during measurement > Vs ~ 40 % Velocity during measurement < Vs ~ 40 % 1.0 < Vs < 10 }0.5 % of rate }0.2 % of Vs 0.1 < Vs < 1.0 }(0.1/Vs+0.4)% of rate }0.4(0.1/Vs+0.4)% of Vs Vs (m/s) Velocity during measurement >Vs ~ 40 % Standard Accuracy (Calibration Code A) *)High Accuracy (Calibration Code U) 1.0 < Vs < 10 }0.5 % of rate }0.35 % of rate 0.1 < Vs < 1.0 }(0.1/Vs+0.4)% of rate }(0.1/Vs+0.25)% of rate Vs (m/s) Velocity during measurement < Vs ~ 40 % Standard Accuracy (Calibration Code A) *)High Accuracy (Calibration Code U) 1.0 < Vs < 10 }0.1 % of Vs }0.07 % of Vs 0.1 < Vs < 1.0 }0.2(0.1/ Vs+0.4)% of Vs }0.2(0.1/Vs+0.25)% of Vs