【DO!BOOK・ページリンク】 fi-04 40 / 228 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-MGG200-0100 - 15 - Wafer type (25 to 200 mm (1 to 8 inches)) Polyurethane rubber lining Model MGG18D - I II III IV V VI VII VIII IX - X XI - Y / Options (some options can be selected per each model) Basic model no. Selections Optional selections MGG18D - - I Line size 25 mm (1 inch) 025 40 mm (1. inches) 040 50 mm (2 inches) 050 65 mm (2. inches) 065 80 mm (3 inches) 080 100 mm (4 inches) 100 125 mm (5 inches) 125 150 mm (6 inches) 150 200 mm (8 inches) 200 II Lining Polyurethane rubber Q III Piping connection Wafer JIS 10K 11 Wafer JIS 20K 12 Wafer JIS 30K 13 Wafer ANSI 150 21 Wafer ANSI 300 22 Wafer JIS G3443-2 F12 (line size 80 mm or larger) 31 Wafer DIN PN10 41 Wafer DIN PN16 42 Wafer DIN PN25 43 Wafer DIN PN40 44 Wafer JPI 150 61 Wafer JPI 300 62 IV Electrode SUS316L L Titanium K Tungsten carbide (only for size 10 mm) W Others .. V Grounding ring SUS316 S Titanium K Others .. VI Electrical connection / watertight gland Integral type 1 Remote type G1/2 internal thread / without watertight gland 2 G1/2 internal thread / with brass (Ni-plated) watertight gland 3 G1/2 internal thread / with plastic watertight gland 4 1/2NPT internal thread / without watertight gland (Note 1) 5 CM20 internal thread / without watertight gland 6 Pg 13.5 internal thread / without watertight gland 7 G1/2 internal thread / with SUS304 watertight gland 8 VII Face-to-face dimensions Standard A VIII Installation / wiring direction Integral type H Remote type Upstream side (horizontal / vertical piping mounting) A Downstream side (horizontal / vertical piping mounting) B Horizontal piping mounting / left side viewed from upstream C Horizontal piping mounting / right side viewed from upstream D IX Calibration Standard A +/- 0.35 % of rate calibration (Size 40 to 200 mm (1 1/2 to 8 inches)) U Others .. X Finish Standard X Corrosion-resistant finish 1 Corrosion-proof finish 2 XI Bolt / nut None X Carbon steel 1 SUS304 2 Options Azbil Corporation version (must be selected) Y Note: 1. Must be selected for CSA/FM NI approval 2. Must be selected for Tag no. requirement Traceability certificate for detector B Material certificate (only for electrodes and ground rings) C With gasket for plastic piping J Attachment of the TAG number to the terminal box for detector (Note 2) K 4 3 |