No. SS2-MGG200-0110 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS Type of protection JIS C 0920 waterproof model NEMA ICS6-110 TYPE4 IEC PUBL 529 IP66 Ship classification Approved by NK (Nippon Kaiji Kyokai) Approval No.: 11A008 Note: The MGG18D cannot be installed on the bridge or deck of the ship. In the case of a remote model, the cables between the converter and detector must be covered with a flexible metal conduit. Temperature range of liquid to be measured Ceramic lining Thermal shock Increase ..T= 150°C (270°F)/sec max. Decrease ..T= 100°C (180°F)/sec max. Measurable process fluid pressure Measurable electrical conductivity Combined with model MGG14C converter 3 μS/cm or more (in case of less than 3 μS/cm, consult an Azbil Corp. representative) Vibration effect Integral style: 4.9 m/s2(0.5G) max. Remote style converter: 4.9 m/s2(0.5G) max. Remote style detector: 19.6 m/s2(2G) max. Measurement flow range Refer to the minimum/maximum set ranges shown in the table below. Measurement flow velocity range 0 to 10 m/s Flange rating JIS 10K, 20K, 30K, 40K ANSI 150, 300, JPI 150, 300 DIN PN10, 16, 25, 40 JIS G3443-2 F12 (diameter 80 to 100 mm) Reference flange standard JIS; JIS B2210 (1984) ANSI; ANSI B16.5 (1988) JPI; JPI-7S-15-93 Ambient temperature limits -25 to +60°C (integral model) -30 to +80°C (integral model) Ambient humidity limits 10 to 90 % RH Optional specifications Test report Calibration certificate, withstand voltage test, insulation resistant, hydrostatic pressure test, physical inspection are included. Traceability certificate The following three documents are included. . Traceability system chart . Traceability certificate . Test report Attaching the tag number to the terminal box Stamp the tag with the specified number and attach to the terminal box. The maximum number of characters in the tag number is 8. Attaching the tag number to the neck section Stamp the tag with the specified number and attach to the neck section of the detector. The maximum number of characters in the tag number is 16. Diameter (mm) Temperature of the liquid to be measured Integral model Remote model 15 to 100 -40 to +120°C -40 to +180°C 3.92MPa -0.098 MPa -40 C 120 C Integral style 3.92MPa -0.098 MPa -40 C 180 C Remote style Diameter (mm) Minimum set range (m3/h) (Minimum constant flow speed of 0 to 0.1 m/s) Maximum set range (m3/h) (Maximum constant flow speed of 0 to 0.1 m/s) Flow conversion factor K 15 0 to 0.0637 0 to 6.36 1.572 25 0 to 0.177 0 to 17.6 0.5659 40 0 to 0.453 0 to 45.2 0.2210 50 0 to 0.707 0 to 70.6 0.1415 80 0 to 1.81 0 to 180 0.005526 100 0 to 2.83 0 to 282 0.03537 |