No. SS2-MGG200-0200 Azbil Corporation - 2 - APPLICATIONS Model MGG17 can be used for Division 1 location. Petroleum / petrochemical / chemicals Corrosive liquids, dyestuffs, chemicals, industrial water, waste water, etc. Shipbuilding Sediment slurry etc. Electric power Corrosive liquids, cooling water, industrial water, wastewater, etc. Gas Circulating water for air conditioning, etc. FUNCTIONAL SPECIFICATIONS Type of protection Enclosure rating JIS C 0920 watertight model NEMA ICS6-180 TYPE4X IEC PUBL 529 IP67 Hazardous areas certifications FM/CSA explosionproof Class I, Division 1, Groups B, C, and D; Class II, Division 1, Groups E, F and G; Class III, Division 1 locations. (Only electrodes within the detector are of intrinsically safe circuits) Ship classification Approved by NK (Nippon Kaiji Kyokai) Approval No.: 11A008 Note: . The MGG17 cannot be installed on the bridge or deck of the ship. In the case of a remote model, the cables between the converter and detector must be covered with a flexible metal conduit. Line size 2.5, 5, 10, 15, 25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400 mm (0.1, 0.2, 3/8, 1/2, 1, 1., 2, 2., 3, 4, 5, 6, 8, 10, 12, 14, 16 inches) Temperature range and pressure range of process fluid Measurable electrical conductivity Combined with model MGG14C converter 3 ..S/cm or more Size 250 to 400 mm (10 to 16 inches) Size 15 to 200 mm (1/2 to 8 inches) Size 2.5 to 10 mm (0.1 to 3/8 inch) 2.94 MPa (426 psi) 1.96 MPa (284 psi) -0.098 MPa (-14.2 psi) 2.94 MPa (426 psi) -0.098 MPa (-14.2 psi) -40 (-40) 80 (176) 100 C (212 F) 0.098 MPa (142 psi) 1.96 MPa (284 psi) -0.098 MPa (-14.2 psi) 0.098 MPa (142 psi) -40 (-40) 80 (176) -40 (-40) 100 (212) 120 C (248 F) 120 C (248 F) |