Azbil Corporation No. SS2-MGG200-0200 - 3 - Measurement flow range. Flange rating JIS10K, JIS16K, JIS20K, JIS30K, JPI150, JPI300, ANSI150, ANSI300, DIN PN10, DIN PN16, DIN PN25, DIN PN40 (size 2.5 to 50 mm (0.1 to 2 inches)) JIS10K, JIS16K, JIS20K, JIS30K, JPI150, JPI300, ANSI150, ANSI300, DIN PN10, DIN PN16, DIN PN25, DIN PN40, (size 80 to 200 mm (3 to 8 inches)) JIS10K, JIS16K, JIS20K, JPI150, JPI300, ANSI150, ANSI300, DIN PN10, DIN PN16, DIN PN25, (size 250 to 400 mm (10 to 16 inches)) Ambient temperature limits -10 to +60°C (+14 to +140°F) Ambient humidity limits 5 to 100 % RH Optional specifications Test report Calibration certificate, withstand voltage test, insulation resistant, hydrostatic pressure test, physical inspection are included. Traceability certificate The following three documents are included. . Traceability System Chart . Traceability Certificate . Test Report Material certificate Material certificate for electrode/grounding ring Gasket for plastic piping When the detector is being mounted on plastic pipe, attach this gasket between the lining and the grounding ring, and between the grounding ring and the plastic pipe flange. Attaching the tag number to the terminal box Stamp the tag with the specified number and attach to the terminal box. The maximum number of characters of the tag number is 8. Attaching the tag number to the neck section Stamp the tag with the specified number and attach to the neck section of the detector with stainless wire. The maximum number of characters of the tag number is 16. Refer to the minimum/maximum set ranges shown in the table below Size Minimum flow velocity range is 0 to 0.1 m/s (0 to 0.33 ft/s) Maximum flow velocity range is 0 to 10 m/s (0 to 32.8 ft/s) conversion Minimum range Maximum range factor K mm inch m3/h GPM m3/h GPM 2.5 0.1 0 to 0.001768 0 to 0.007782 0 to 0.1767 0 to 0.7781 56.59 5 0.2 0 to 0.007069 0 to 0.03113 0 to 0.7068 0 to 3.112 14.15 10 3/8 0 to 0.02828 0 to 0.1246 0 to 2.827 0 to 12.45 3.537 15 1/2 0 to 0.06362 0 to 0.2802 0 to 6.361 0 to 28.01 1.572 25 1 0 to 0.1768 0 to 0.7782 0 to 17.67 0 to 77.81 0.5659 40 1. 0 to 0.4524 0 to 1.993 0 to 45.23 0 to 199.2 0.2210 50 2 0 to 0.7069 0 to 3.113 0 to 70.68 0 to 311.2 0.1415 65 2. 0 to 1.195 0 to 5.261 0 to 119.4 0 to 526.0 0.08371 80 3 0 to 1.810 0 to 7.969 0 to 180.9 0 to 796.8 0.05526 100 4 0 to 2.828 0 to 12.46 0 to 282.7 0 to 1245 0.03537 125 5 0 to 4.418 0 to 19.46 0 to 441.7 0 to 1945 0.02264 150 6 0 to 6.362 0 to 28.02 0 to 636.1 0 to 2801 0.01572 200 8 0 to 11.31 0 to 49.81 0 to 1130 0 to 4980 0.008842 250 10 0 to 17.68 0 to 77.82 0 to 1767 0 to 7781 0.005659 300 12 0 to 25.45 0 to 112.1 0 to 2544 0 to 11205 0.003930 350 14 0 to 34.64 0 to 152.6 0 to 3463 0 to 15251 0.002887 400 16 0 to 45.24 0 to 199.3 0 to 4523 0 to 19920 0.002210 4 5 |