【DO!BOOK・ページリンク】 fi-04 83 / 228 10秒後にBOOKのページに移動します |
|
6 MagneW3000 FLEX (TIIS Explosion-proof Model) (Wafer detector 15 to 200mm) PFA lining Basic Model No. Selections Optional selections Options(Maximum selection:5) MGG15D - - - Diameter 15mm 015 X No option 25mm 025 B Certification of traceability 40mm 040 C Mill sheet 50mm 050 E Moisture treatment 65mm 065 F Oil removal treatment 80mm 080 J Gasket for resin pipe (for general purposes) 100mm 100 K 125mm 125 150mm 150 .. Others 200mm 200 Lining PFA P Pipe connection Wafer JIS10K 11 Wafer JIS20K 12 Wafer JIS30K 13 X Finish Standard Wafer ANSI150 21 1 Corrosion-resistant finish Wafer ANSI300 22 2 Corrosion-proof finish Wafer JIS G3451 F12 (Diameter 80mm or more) 31 Wafer DIN PN10 41 X Bolt/nuts None Wafer DIN PN16 42 1 Carbon steel Wafer DIN PN25 43 2 SUS304 Wafer DIN PN40 44 Wafer JPI150 61 Wafer JPI300 62 Pipe combine Wafer X Electrodes SUS316L L ASTM B574(Hastelloy C-276 equivalent) C Titanium K Zirconium H Tantalum T Tungsten carbide W Platinum iridium P Others .. Grounding ring SUS316 S ASTM B575(Hastelloy C-276 equivalent) C Titanium K Zirconium H Tantalum T Platinum P Others .. Wiring connection/ G1/2 internal thread/With flame-proof cable gland 1 Cable adapter Face to face Standard A Others .. Installation/ Upstream side A Wiring direction Remote Downstream side B model Horizontal piping mounting/Left side viewed from upstream C Horizontal piping mounting/Right side viewed from upstream D Calibration/ Standard calibration A Approval Others .. TAG number plate attached to the terminal box (remote detector) |