Azbil Corporation No. SS2-MGW200-0100 - 3 - PERFORMANCE SPECIFICATIONS Accuracy (in combination with the model MGG14C converter) Velocity ±0.8 to 8m/s (2.62 to 26.2ft/s) Accuracy; ±0.5% of rate ±3.5mm/s (±0.5% of rate ±0.115ft/s) Velocity ±0 to 0.8m/s (0 to 2.62ft/s) Accuracy; ±6.3mm/s(±0.02ft/s) PHYSICAL SPECIFICATIONS Main body material Measuring pipe materials (non wetted) SUS304 stainless steel Flange (non wetted) Carbon steel Case Carbon steel Terminal box Aluminum alloy Finish Standard Urethane paint Color Light beige Process wetted material Lining Chloroprene rubber Electrode SUS316 Grounding ring SUS304 Electrical connection 1/2NPT internal thread Pipe connection Flange Grounding Resistance less than 100 .. Length of straight pipe Upstream side A minimum five straight pipe diameters A minimum 10 straight pipe diameters is required if a diffuser/valve/pump is installed upstream side. Downstream side Two straight pipe diameters is recommended. Cable (between remote detector and converter) Maximum length 200 m (656 ft.) (depends on fluid conductivity) Outer diameter 10 to 12 mm (0.4 to 0.47 inch) Signal cable Recommended cable: MGA12W (O.D. 11.4mm (0.44inch), 0.75 mm2(0.0012in2) or equivalent (CVVS, CEEV etc.) Excitation cable Recommended cable: MGA12W (O.D. 10.5 mm(0.41inch), 2 mm2(0.0003in2) or equivalent (CVV and others) Accuracy (% of rate) 0.0% 1.0% 2.0% 3.0% 4.0% 5.0% 6.0% 7.0% 8.0% 9.0% 0.00 5.00 10.00 15.00 20.00 25.00 30.00 Velocity(ft/s) 4 7 |