No. SS2-SLX100-0100 Azbil Corporation - 8 - SEMI-STANDARD SPECIFICATIONS 1. Stainless steel bolt (Y131): For this feature, SUS304 bolts are used for main body assembly. This will be a certified product under High Pressure Gas Law. If the connecting size is JIS10K, NASI150 or JPI150, please consult an Azbil Corp. representative. 2. Silver corrosion proof (acrylic) paint (Y138D) For the prevention of temperature rise by sunlight or radiation heat, as well as protection against corrosive atmosphere. (Note: This does not apply to alkali atmosphere) 3. High pressure gas certification (Y2054) Please refer to the following for scope of manufacture: Scope of liquid level instrument manufacture as certified by Minister for high pressure gas types: 1)-1 Title of certification: Liquid level measurement, float type (including welding construction) 1)-2 Scope of certified specifications: Refer to Table 7 "Scope of certified specifications" for design temperatures, pressures and connecting sizes. 1)-3 The listing in Table 7 shows scope of certified specifications, not a scope of certified liquid level meter manufacturing. The scope of manufacture of the certified liquid level meter is within the temperatures and pressures listed in the Spec. Sheet. Note) * When using SF440A. However, the standard material is SFVC2A, temperature will be “0 °C or higher”. Attention in usage . Azbil Corporation's standard Displacement type level transmitter measurement range is set equivalent to float length H. Therefore, it will be unsuitable when detecting the levels around 0 % or 100 % (at normal operation), or when continuous output of 4mA or less or 20 mA or more is needed. . When conducting the actual liquid adjustment (filling adjustment) after installing the displacement type level transmitter at the job site, be sure to set the float bottom to zero point (reference point at 0 % liquid level). (Structurally, if the measurement fluid is not in contact with float, output will not change.) If other than the float bottom is set to zero point (reference point at 0 % liquid level), it may cause the measurement dead-band at the measurement range of lower limit (or upper limit), or may cause output linearity error. Figure 7 Appropriate way of adjustment: Set float bottom at zero point Figure 8 Inappropriate way of adjustment: set other than the float bottom at zero point Communicator Operation Parameter setting (1) Damping: 0~100 sec. (2) Specific gravity: 0.1~1.6 *Note (3) Burnout: NON, UP, DOWN (4) Span: Set freely within specified range Calibration 1. Zero adjustment *1 2. Span adjustment 3. Exact adjustment *2 Table 7 Scope of certified specifications Certific ate No. MAB-342-0-2 Type of equipm ent Other accessories Description (Type) Material Design temperature Design pressure (Mpa) Connecting dia.(A) Others Class Group Max. °C Min. °C Liquid level meter (Buoyancy type) Carbon steel G4 450 -10 * Under 6.4 Under 125 Stainless steel G1 400 -196 Under 6.4 Under 125 G4 800 -269 Under 6.4 Under 125 G6 800 -196 Under 6.4 Under 125 Zero point Measuring range Float length H Measuring range Zero point Zero point Measurement dead-band Measurement Measuring dead-band range |