【DO!BOOK・ページリンク】 fi-07 8 / 26 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-SLX100-0100 - 5 - Note) The float weight in the above table is for liquid level application. For interface or hyarometer applications, below conditions will apply: 1. Medium specific gravity (model SLX110): Identical to the figures above, 2. Low specific gravity application (model SLX120): Depends on customer's specifications. (Weight for liquid level specifications will be the minimum and it will increase depending on customer's specifications) Table 4 Float test pressure - Material: SUS316L Model No. Measuring range (mm) Medium specific gravity (model SLX110) Low specific gravity (model SLX120) Float dia. (mm) Weight (Kg) With standing pressure (MPa) Flange rating Float dia. (mm) Weight (kg) With standing pressure (MPa) Flange pressure rating (MPa) 03 0 to 300 55 1.8 15.0 Up to JIS 63K, ANSI /JPI 600 95 3.4 7.8 Up to JIS 30K, ANSI /JPI 300 A3 0 to 350 2.2 3.8 04 0 to 400 2.2 4.2 A4 0 to 450 2.2 4.2 05 0 to 500 2.6 4.6 06 0 to 600 45 2.2 85 3.4 3.2 Up to JIS10K, ANSI / JPI 150 07 0 to 700 2.2 3.8 08 0 to 800 2.6 4.2 10 0 to 1000 3.0 5.0 12 0 to 1200 30 1.8 65 3.8 15 0 to 1500 2.2 4.2 20 0 to 2000 3.0 55 4.2 Table 5 Float test pressure - Material: Hastelloy C Model No. Measuring range (mm) Medium specific gravity (model SLX110) Low specific gravity (model SLX120) Float dia. (mm) Weight (Kg) With standing pressure (MPa) Flange rating Float dia. (mm) Weight (kg) With standing pressure (MPa) Flange pressure rating (MPa) 03 0 to 300 55 1.8 7.8 Up to JIS 30K, ANSI / JPI 300 95 3.8 7.8 Up to JIS30K, ANSI /JPI 300 A3 0 to 350 2.2 3.4 04 0 to 400 2.2 3.8 A4 0 to 450 2.2 4.2 05 0 to 500 2.6 4.2 06 0 to 600 45 2.2 85 4.2 3.2 Up to JIS10K, ANSI / JPI 150 07 0 to 700 2.2 4.6 08 0 to 800 2.6 5.0 10 0 to 1000 3.0 5.0 12 0 to 1200 30 1.8 65 3.4 15 0 to 1500 2.2 4.2 20 0 to 2000 3.0 55 4.2 Table 6 Material Model (temp. range) Part U M A E D W (350 to 400 °C) (200 to 350 °C) (0 to 200 °C) (0 to 200 °C) (-196 to 0 °C)*i Note) *i. Available at the range of 0 to 200 °C. (-40 to +200 °C) Housing Aluminum alloy Torque tube inconel SUS316L Hastelloy C Bonnet / chamber Carbon steel (SFVC2A), SUS304, SUS316, SUS316L*ii Note) *ii. If the optional code is “D”, carbon steel cannot be selected. SUS316L Float SUS316L Hastelloy C Bolt Chromium-Molydbenum steel (SNB7) SUS304 Gasket Spring type (Semi-metallic, Filler material: Graphite) Extension SUS304 (Long) SUS304 (Standard) Sensor housing Aluminum alloy casting 7 1 |