- 1 - 8th edition No. SS2-8114-0300 OVERVIEW Model HTS Top Guided Single Seated Control Valves are designed for heavy-duty service. The compact valve body, having an S-shaped flow passage that features low pressure loss, allows a large flow capacity, rangeability, and high-accuracy flow characteristics. The valve plug is highly vibration-resistant as it is held by a top guide section which has a small sliding area. The flow shut-off performance complies with the IEC or JIS Standards. The actuator section performs two-position operation or proportional operation by directly receiving the signal of 4 to 20 mA DC or 1 to 5V DC from the electronic-type controller. The provided electric-type actuator offers high accuracy, compactness, and sturdy structure. The model HTS Valves are widely applicable for reliable control of process lines where high shut-off performance is required. SPECIFICATIONS Body Type: Straight-through, Cast globe valve Nominal size: 1., 2, 2., 3, 4, 6, 8 inches Pressure rating: JIS 10K, 16K, 20K, 30K, 40K ANSI Class 125, 150, 300, 600 JPI Class 125, 150, 300, 600 End connection: Flanged end; Welded end; SW (1., 2 inches), BW (2. ~ 8 inches) Material: For body/trim material combinations and operating temperature ranges, refer to Table 1. Bonnet style: . Plain bonnet: (-17 ~ +230°C) . Extension Type 1: (-45 ~ -17°C and +230 ~ +566°C) Connection type Pressure rating Applicable standard FF JIS10K JIS B2210-1984 ANSI Class 125 ANSI B16.5-1981 JPI Class 125 JPI-7S-15-1993 RF JIS10K, 16K, 20K, 30K, 40K JIS B2210-1984 ANSI Class 150, 300, 600 ANSI B16.5-1981 JPI Class150, 300, 600 JPI-7S-15-1993 RJ, LG ANSI Class 150, 300, 600 ANSI B16.5-1981 JPI Class 150, 300, 600 JPI-7S-15-1993 Tongue and groove(groove) Male and female(female) JIS16K, 20K, 30K, 40K JIS B2202-1984 . Extension Type 2: Integral cast type (-100 ~ -45°C) Welded type (-196 ~ -100°C) . Bellow type: (For operating temperature and pressure range, refer to Figure 3.) Note) Take care not to exceed the operating temperature ranges specified for respective materials. Gland type: Bolted gland Packing/grease: . Grease not provided; When V shaped PTFE packing or PTFE yarn packing is used. . Grease provided; When graphite packing is used. Note) PTFE: Polytetrafluoroethylene. Gasket: Type; Flat type, serrated type Material; Carbon steel (S15C) stainless steel (SUS316, SUS316L, SUS329J1), copper, aluminum, titanium, ASTM B574 (Hastelloy C-276 equivalent), or alloy 20 CV3000 Series Electric Top-Guided Single Seated Control Valve Model HTS 6 3 Specifications are subject to change without notice. “This product is designed for general industrial use.” |