【DO!BOOK・ページリンク】 cv-07 130 / 138 10秒後にBOOKのページに移動します |
|
- 1 - 7th edition No. SS2-8310-0400 OVERVIEW The Pneumatic Valve Positioners (VPE) are designed specifically for small actuators for the CV3000 Alphaplus Series valves, the CV3000 Series valves, NEW10 Series valves, and Small Flow vavles to improve characteristics and response of control valves as well as to minimize the effect of changes in fluid pressures. FEATURES 1) The VPE is compact and can be readily installed in small actuators. 2) All of the major components are housed in the casing and purged with bleeding air, there by preventing corrosion caused by adverse atmosphere. 3) The VPE provides an air booster mechanism. Although compact, the VPE allows a rapid response speed which is comparable with that of a large positioner. 4) The VPE can be effectively used when the controller signal span and the actuator spring span do not mutually conform, so that the valve position can be controlled in direct conformity with the controller signal. SPECIFICATIONS Model Output characteristics: Linear Supply air pressure: 140 to 390 kPa {1.4 to 4.0 kgf/cm2} Air consumption: 9 Nl/min. (normal state, supply air pressure 350 kPa {3.5 kgf/cm2}) Maximum capacity of air flow: 88 Nl/min. (supply air pressure 350 kPa {3.5 kgf/cm2}) VPE04 : Supply air pressure 140 to 190 kPa {1.4 to 1.9 kgf/cm2} (1) VPE05 : Supply air pressure 200 to 390 kPa {2.0 to 4.0 kgf/cm2} Code (1) Input signal Full range 20 to 100 kPa (Standard) 1 Half range 20 to 60 kPa (Low range) 2 Half range 60 to 100 kPa (High range) 3 Air connection: Rc 1/4 internal thread Ambient temperature: -20 to +70 °C Ambient humidity: 10 to 90% PH Performance: Accuracy ; + 3% F.S. Dead band ; 0.3% F.S. Operating speed: 12 mm/s maximum Additional specifications (by special order): Corrosion-resistant and silver finish (Semi-standard specification Y138): . Corrosion-resistant (Acryl baking) finish (Y138A) ; Resistance for corrosive gases. . Corrosion-proof (Epoxy baking) finish (Y138B) ; Resistance for corrosive liquids. . Silver-normal (Acryl baking) finish (Y138C) ; Protection for temperature rise of device caused by direct sun light, radiation heat, etc. . Silver-corrosion-resistant (Acryl baking) finish (Y138D) ; Protection for above-mentioned temperature rise and resistance for corrosive gases. Note) Silver finish is not applicable for alkaline gases. Pneumatic Valve Positioner For Small Actuators Model VPE04/05 7 17 Specifications are subject to change without notice. “This product is designed for general industrial use.” |