【DO!BOOK・ページリンク】 cv-07 134 / 138 10秒後にBOOKのページに移動します |
|
- 1 - 9th edition No. SS2-8310-0300 OVERVIEW Model VPP02/03 double acting type pneumatic valve positioner mounted on the valve is a force-balance servo mechanism designed to position the control valve correctly and rapidly by bleeding or feeding air to the diaphragm, double acting actuation in accordance with the pneumatic signal from a controller. SPECIFICATIONS Model Output characteristics: Linear, Equal percentage and Quick opening. Supply air pressure: 200 to 690 kPa {2.0 to 7.0 kgf/cm2} Air consumption: 20 Nl/min. (normal state, supply air pressure 490 kPa {5.0 kgf/cm2}) Maximum capacity of air flow: 250 Nl/min. (supply air pressure 490 kPa {5.0 kgf/cm2}) Pneumatic tubing connection: Rc 1/4 Ambient temperature: -30 to +80 °C Performance: Accuracy ; + 1% F.S. Dead band ; 0.5% F.S. Travel adjustable range: 14 to 100 mm VPP02 : Supply air pressure 200 to 340 kPa {2.0 to 3.5 kgf/cm2} (1) VPP03 : Supply air pressure 350 to 690 kPa {3.6 to 7.0 kgf/cm2} Code (1) Input signal Full range 20 to 100 kPa (Standard) 1 Half range 20 to 60 kPa (Low range) 2 Half range 60 to 100 kPa (High range) 3 Additional specifications (by special order): Corrosion-resistant and silver finish (Semi-standard specification Y138): . Corrosion-resistant (Acryl baking) finish (Y138A) ; Resistance for corrosive gases. . Corrosion-proof (Epoxy baking) finish (Y138B) ; Resistance for corrosive liquids. . Silver-normal (Acryl baking) finish (Y138C) ; Protection for temperature rise of device caused by direct sun light, radiation heat, etc. . Silver-corrosion-resistant (Acryl baking) finish (Y138D) ; Protection for above-mentioned temperature rise and resistance for corrosive gases. Note) Silver finish is not applicable for alkaline gases. Weight: 3.5 kg Housing material: Aluminum alloy casting Finish: Acryl baking finish (For corrosion-resistant and silver finish, refer to the optional specification.) Color of finish: Dark beige (Munsell 10YR 4.7/0.5) Double Acting Type Pneumatic Valve Positioner Model VPP02/03 7 19 Specifications are subject to change without notice. “This product is designed for general industrial use.” |