No. SS2-AVP703-0100 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS Applicable actuator . Single and double acting actuator . Linear and rotary motion actuator Approvals TIIS Flameproof Ex d IIC T6 FM Explosionproof / Dust Ignition Protection Explosionproof (Division system):Class I, Division 1, Group B, C, D T6 . Factory sealed, conduit seal not required . Not including gasoline atmospheres Flameproof (Zone system): Class I, Zone 1, AEx d IIC Gb Dust ignition protection (Division system): ClassII, III, Division 1, Group E, F , G T6 Dust ignition protection (Zone system):Zone21 AEx tb IIIC T85 ‹C Db Enclosure classification:IP66 FMC Explosionproof / Dust Ignition Protection Explosionproof (Division system): ClassI, Division1, Group C, D T6 . Factory sealed, conduit seal not required . Not including gasoline atmospheres Flameproof (Zone system): Class I, Zone 1, Ex d IIB T6 Seal all conduits within 450 mm (18 inches) Dust ignition protection (Division system): Class II, III, Division 1, Group E, F, G T6 Enclosure classification: IP66 ATEX Flameproof / Dust Ignition Protection Flameproof: II 2 G Ex d IIC T6 Gb Dust ignition protection: II 2 D Ex tb IIIC T85 ‹C Db Enclosure classification: IP66 Cables glands or conduit sealing devices used must be sertified for the Ex d IIC protection. Use the product with the degree of protection IP66 under the IP66 required environment. IECEx Flameproof / Dust Ignition Protection Flameproof: Ex d IIC T6 Gb Dust ignition protection: Ex tb IIIC T85 ‹C Db Enclosure classification: IP66 Cables glands or conduit sealing devices used must be sertified for the IECECo Ex d IIC protection. Use the product with the degree of protection IP66 under the IP66 required environment. NEPSI Flameproof / Dust Ignition Protection Flameproof: Ex d IIC T6 Gb Dust ignition protection: DIP A21 TA 85 ‹C Enclosure classification: IP66 Cables glands or conduit sealing devices used must be sertified for the Ex d IIC or DIP A21 protection. Use the product with the degree of protection IP66 under the IP66 required environment. EAC Flameproof Flameproof: 1Ex d IIC T6 Enclosure classification: IP66 Cables glands or conduit sealing devices used must be sertified for the EAC 1Ex d IIC or IECEx Ex d IIC protection. Use the product with the degree of protection IP66 under the IP66 required environment. INMETRO Flameproof / Dust Ignition Protection Flameproof: Ex d IIC T6 Gb Dust ignition protection: Ex tb IIIC T85 ‹C Db Enclosure classification: IP66 Cables glands or conduit sealing devices used must be sertified for the INMETRO or IECEx Ex d IIC or Ex td IIIC protection. Use the product with the degree of protection IP66 under the IP66 required environment. Output characteristics . Linear, Equal percentage, Quick opening . Custom configurable 21 segments Stem travel range Feedback Lever Angle }4‹ to }20‹ Bypass operation Auto/Manual external Switch (For single acting type only) Air supply pressure 140 to 700 kPa {1.4 to 7.0 kgf/cm2} Air consumption at the stable output 50% 3.2 ../min (N) maximum at 140 kPa {1.4 kgf/cm2} 4.0 ../min (N) maximum at 280 kPa {2.8 kgf/cm2} 4.8 ../min (N) maximum at 500 kPa {5.0 kgf/ cm2} 8 ../min (N) maximum at 400kPa {4.0kgf/cm2} for double acting type Maximum air deliver flowrate 110 ../min (N) at 140 kPa {1.4 kgf/cm2} Lightning protection Peak value of voltage surge: 12 kV Peak value of current surge: 1000 A Vibration tolerance 2 G (5 to 400 Hz) (with standard mounting kit on Azbil Corporation HA actuator) Ambient temperature limits Waterproof: -40‹C to +80‹C (LCD: 0 to +50‹C) TIIS Flameproof: -20‹C to +55‹C FM/FMC/ATEX/IECEx/NEPSI/EAC/INMETRO Explosion protection: -30‹C to +75‹C CE conformity Electromagnetic compatibility EN61326-1: 2013 (CE marking) Ambient humidity limits 5% to 100% RH |