No. SS2-AVP772-0100 Azbil Corporation NEPSI Flameproof / Dust Ignition Protection Flameproof: Ex d IIC T6 Gb Dust Ignition Protection: DIP A21 TA 85 °C Container Protection Grade: IP66 Please use Ex d IIC or DIP A21-approved products as the cable ground .............................. to the electrical connection port. ..lease use IP66-approved products in an environment that requires IP66. KOSHA Flameproof: Ex d IIC T6 Please use Ex d IIC-approved products as the cable ground .............................. to the electrical wiring port. EAC Flameproof: 1Ex d IIC T6 X Container Protection Grade: IP66 Please use EAC 1Ex d IIC-approved products, or IECEx Ex d IIC-approved products as the cable ground .............................. to the electrical connection port. ....ease use IP66-approved products..in an environment that requires IP66. INMETRO Flameproof / Dust Ignition Protection Flameproof: Ex d IIC T6 Gb Dust Ignition Protection: Ex tb IIIC T85 °C Db Container Protection Grade: IP66 Please use INMETRO or IECEx Ex d IIC and Ex td IIIC-approved products as the cable ground to be connected to the electrical wiring port. ....ease use IP66-approved products in an environment that requires IP66. Electrical standard CE Marking (EN61326-1: 2013) Related devices Field Communication Software CommStaff Model CFS 100 525 247 0 17.9 24 45 1,484 Supply Voltage E (VDC) Operative Limit Range External Load Resistance R (Ω) Normal Operating Range 42 1,347 E - 12.5 0.0219 R = Figure 1. Supply Voltage and External Load Resistance of the Travel Transmission Table 1 - Stroke and Accuracy of the Standard Operating Unit Actuator Stroke [mm] Accuracy [%FS] PSA1, 2 14.3, 20, 25 1.0 PSA3, 4 20, 38 1.0 HA1 6, 8, 10 3.0 14.3, 25 1.0 HA2 10 3.0 14.3, 25, 38 1.0 HA3 14.3 3.0 25, 38, 50 1.0 HA4 14.3 3.0 25, 38, 50, 75 1.0 VA5 25, 37.5, 50, 75, 100 1.0 VA6 PSA6, 7 14.3 3.0 25, 37.5, 50, 75, 100 1.0 HK1 PSK1 10 3.0 19 1.0 DAP560, 1000 1000X 14.3 3.0 25-100 1.0 DAP1500, 1500X 14.3, 25 3.0 38-100 1.0 Air Specifications of Applicable Instruments (according to JIS C1805-1 (2001)) Item Specifications Solid particles There must be no particles with diameter that exceeds 3 μm. Oil content The mass must be less than 1 ppm Supply air temperature Dew point temperature must be at least 10 °C lower than temperature of the main unit Please appropriately install the following air cleaner at each of the installation locations to satisfy the above instrumentation air specification. Examples of Air Cleaners Installation Locations Air Cleaners SMC Inc. CKD Inc. Compressor outlet or mainline Line Filter AFF Series AF Series Mist separator AM series For terminals Air combination AW30 M3000S Type 4 |