yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz cv-07@@@47 / 138 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-AVP300-0100 Azbil Corporation - 2 - Travel transmission The model AVP301 transmits a 4.20 mA signal proportional to the valve travel. The valve travel can be monitored from the control room. China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. FUNCTIONAL SPECIFICATIONS Applicable actuator Single and double acting actuator Linear and rotary motion actuator Approvals TIIS Flameproof approval Ex d IIC T6 Certificate No. TC16388 KOSHA Flameproof approval Ex d IIC T6 FM Explosionproof approval Explosionproof for Class I, Division 1, Group A, B, C, D Dust-ignition for Class II, Division 1, Group E, F, G Suitable for Class III, Division 1 Flameproof for Class I, Zone 1, AEx d IIC T6 at Ambient temperature < 80‹C Installation should comply with NEC. FM Intrinsically safe approval Intrinsically safe for Class I, II, III, Division 1, Group A, B, C, D, E, F, G, T4 Intrinsically safe for Class I, Zone 0, AEx ia IIC T4, Ta=80‹C Nonincendive for Class I, Division 2, Group A, B, C, D, T5, Ta=80‹C Suitable for Class II, Division 2, Group F, G, T4, Ta=80‹C The barriers should be FM recognized types and comply with the following conditions as follows. Input signal line: 12.02 . Vmax . 30V, Imax=100mA, Pmax=1W, Ci=0ƒÊF, Li= 0.22mH For travel transmission line: Vmax=30V, Imax=100mA, Pmax=1W, Ci=0.07ƒÊF, Li=0.22mH Installation should comply with NEC. ISSeP/ATEX Flameproof approval II 2 G EEx d IIC T6 at -20‹C < Tamb < +70‹C IEC IP66 Certificate No. ISSeP 02ATEX056 Flameproof cable gland must be ATEX approved. KEMA/ATEX Intrinsically safe approval II 1 G Ex ia IIC T4 II 1 D Ex iaD 20 IP66 T135‹C Certificate No. KEMA 00ATEX1111 X IEC IP66 The barriers should be ATEX certified types and comply with the following condition as follows. Input circuit (terminals }IIN) Ui = 30 V, Ii = 100 mA (resistively limited), Pi = 1 W, Ci = 1 nF, Li = 0.2 mH Output circuit (terminals }IOUT) Ui = 30 V, Ii = 100mA (resistively limited), Pi = 1 W, Ci = 3 nF, Li = 0.2 mH Both circuits shall be considered to be connected to ground from a safety point of view. CSA Explosionproof approval Explosionproof for Class I, Division 1, Group B, C, and D Flameproof for Class I, zone 1, Ex d IIC, T6 Dust ignition proof for Class II and III Division 1, Group E, F and G Type 4X, Certificate No. 188352-1028066 (LR113752-6) NEPSI Flameproof approval Ex d IIC T6, with NEPSI Dust ignition DIP A20 Ta T6 Flameproof cable gland must be NEPSI approved. NEPSI Intrinsically safe approval Ex ia IIC T4-T6 The barriers should be NEPSI certified types and comply with the following condition as follows. Input circuit (terminals }IIN) Ui = 30 V, Ii = 95 mA Pi = 0.66 W, Ci = 0ƒÊF Li = 0.2 mH Output circuit (terminals }IOUT) Ui = 30 V, Ii = 95 mA Pi = 0.66 W, Ci = 0ƒÊF Li = 0.2 mH Combination of NEPSI Flameproof and Intrinsically safe When used as NEPSI Flameproof, it complies NEPSI Flameproof approval as above, When used as NEPSI Intrinsically safe, it complies NEPSI Intrinsically safe approval as above. Control signal input 4.20 mA DC (Configurable any required range for split range, minimum span: 4 mA DC), minimum driving current: 3.85 mA. In case of model AVP301 when signal input is less than 3.85 mA, output current will be burnout. |