Azbil Corporation No. SS2-AVP300-0100 - 7 - Note) *1 Select gYWh or gYJh for old-type motion connectors. (Produced on/before Apr.f83) *2 Consult with sales representative in case of no mounting hole on the side of valve yoke. *3 Select in the case of without manual handle or with manual handle mounted on top of the actuators. *4 Additional support bracket is required. *12 In case gVMh type actuator is required following conditions, 1. select model gVCTh for the body, 2. the existing positioner should be HEP or VPE, 3. yoke should be model HK. If another spec. is required, contact your sales representative. Table 2 Mounting bracket for single acting actuator (8)(9) Mounting bracket for pneumatic actuators Code PSA1, PSA2, PSK1 YS PSA3, PSA4 / VA1 to VA3 produced after Apr.f83*1 YQ PSA3, PSA4 for existing valves produced on/ before 1999 YY PSA6 / VA4 to VA6 produced after Apr.f83 *1 YL PSA7 Y8 HA1 YA HA2, HA3, HL2, HL3 YT HA4, HL4 YN HK1, VM1 *12 YK VM12 for model VSP *4 YB VR1 YV VR2, VR3 YR VR3H Y6 RSA1 YF RSA2 YU GOM 83S, GOM 84S, GOM 103S YG GOM 124S YM VA1 - VA3 (for old-model motion connectors) Produced on/before Apr.e83 800-1, 800-3 *2 YW VA4 - VA5 (for old-model motion connectors) Produced on/before Apr.e83 800-4, 800-5 *2 YJ Motoyama Mfg. 2800 series 240, 280, 330, Nihon Koso A100 series 270, 320 *3 TA Motoyama Mfg. 2800 series 400, 500S, 500L, Nihon Koso A100 series 400, 500 *3 TB Motoyama Mfg. 2800 series 650S, 650L TC Motoyama Mfg. 2800 series 240, 280, 330 (with side manual) TD Motoyama Mfg. 2800 series 400, 500S, 500L (with side manual) TE Motoyama Mfg. 2800 series 650S, 650L (with side manual) TF Motoyama Mfg. 3800 series (multi-spring type) N24, N28, N33S TJ Motoyama Mfg. 2922 series (Gyrol-I) G.R.I 280H, 330H, 400HS, 400H, 500H TL Motoyama Mfg. 3993 series (Gyrol-II) 2911-1M series 280, 330, 400 TG Nihon Koso 5100L series 240, 280 *3 TP Nihon Koso 5200L series 218, 270, 350 *3 TR Masoneilan 37, 38 series #9, #11 *3 MA Masoneilan 37, 38 series #13 *3 MB Masoneilan 37, 38 series #15, #18 *3 MC Masoneilan 37, 38 series #15, #18 (with side manual) MF Masoneilan type 35002 series Camflex II #41/2, #6, (Valve size 1 inch - 4 inches) MG Masoneilan type 35002 Camflex II #7 (Valve size 6 inches - 12 inches) MH Fisher 657, 667 series size 40 FB Fisher 657, 667 series size 45, 50 FC Fisher 657, 667 series size 60 FD Pentair Valve and Control Japan AK09S, AK12S, AK15S KA Pentair Valve and Control Japan AG06S, AGN06S KG Pentair Valve and Control Japan AG09S, AGN09S KH Pentair Valve and Control Japan AG13S, AGN13S KJ Pentair Valve and Control Japan AW13S KV Pentair Valve and Control Japan AW17S KW Pentair Valve and Control Japan AW20S KT KITZ B series BS-2, BSW-2 B2 KITZ B series BS-3, BSW-3, Hisaka TS-6 B3 KITZ B series BS-4, BSW-4 B4 KITZ B series BS-5, BSW-5 B5 KITZ B series BS-6, BSW-6 B6 Xomox (EL-O-MATIC) E25, 40, 65, 100, 200, 350 RA Xomox (EL-O-MATIC) E600, 950, 1600, P2500, P4000 RB Hisaka TS-1 H1 Hisaka TS-2 H2 Hisaka TS-3 H3 Hisaka TS-4, 5 H4 Tomoe Valve Z series Z-06S, 08S, 11S, 13S EA Tomoe Valve T-matic 3Q-1, 2, 3, 4 E3 Table 2 Mounting bracket for single acting actuator (8)(9) Mounting bracket for pneumatic actuators Code 7 4 |