yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz cv-07@@@63 / 138 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-AVP200-0100 Azbil Corporation - 6 - Note) *2 If no suitable mounting bracket can be found, contact a sales representative. *5 Select in the case of without manual handle or with manual handle mounted on top of the actuators. *8 Select gYWh or gYJh for old-type motion connectors. (Produced on/before Apr.f83) *9 Consult a sales representative in case of no mounting hole on the side of valve yoke. *10 In case gVMh type actuator is required following conditions, 1. select model gVCTh for the body, 2. the existing positioner should be HEP or VPE, 3. yoke should be model HK. If another specification is required, contact your sales representative. *13 For model VSP (PVC body), an additional support bracket is required for the AVP. Table 2 Mounting bracket for single acting actuator (8)(9) Mounting bracket for pneumatic actuators Code PSA1, PSA2, PSK1 YS PSA3, PSA4 / VA1 to VA3 produced after Apr.f83 *8 YQ PSA3, PSA4 for existing valves produced on/ before 1999 YY PSA6 / VA4 to VA6 produced after Apr.f83 *8 YL HA1 YA HA2, HA3, HL2, HL3 YT HA4, HL4 YN HK1, VM1 *10 (material SS400 zinc plated) YK VR1 YV VR2, VR3 YR VR3H Y6 RSA1 YF RSA2 YU GOM83S, GOM84S, GOM103S YG GOM124S YM VA1 - VA3 (for old-model motion connectors) produced on/before Apr.e83 800-1, 800-3 *9 YW VA4, VA5 (for old-model motion connectors) produced on/before Apr.e83 800-4, 800-5 *9 YJ Motoyama Mfg. 2800 series 240, 280, 330, Nihon Koso A100 series 270, 320 *5 TA Motoyama Mfg. 2800 series 400, 500S, 500L, Nihon Koso A100 series 400, 500 *5 TB Motoyama Mfg. 2800 series 650S, 650L *5 TC Motoyama Mfg. 2800 series 240, 280, 330 (with side manual) TD Motoyama Mfg. 2800 series 400, 500S, 500L (with side manual) TE Motoyama Mfg. 2800 series 650S, 650L (with side manual) TF Motoyama Mfg. 3800 series (multi-spring type) N24, N28, N33S *5 TJ Motoyama Mfg. 2922 series (Gyrol-I) G.R.I 280H, 330H, 400HS, 400H, 500H TL Motoyama Mfg. 3993 series (Gyrol-II) 280, 330, 400, 2911-1M series 280H, 330H, 400H TG Masoneilan 37, 38 series #9, #11 *5 MA Masoneilan 37, 38 series #13 *5 MB Masoneilan 37, 38 series #15, #18 *5 MC Masoneilan 37, 38 series #15, #18 (with side manual) MF Masoneilan type 35002 series Camflex II #4-1/2, #6, #7 MG Nihon Koso TC-500 series TC520S TP Nihon Koso TC-700 series TC-713S TS Nihon Koso TC-700 series TC-722SS TT Pentair Valve and Control Japan AK05, AK09S, AK12S, AK15S KA Pentair Valve and Control Japan AG06S, AGN06S KG Pentair Valve and Control Japan AG09S, AGN09S KH Pentair Valve and Control Japan AG13S, AGN13S KJ Pentair Valve and Control Japan AW13S KV Pentair Valve and Control Japan AW17S KW Tomoe Valve Z series Z-06S, 08S, 11S, 13S EA Tomoe Valve T-matic 3Q-1, 2, 3, 4 E3 Fisher 657, 667 series 50 FC Fisher 657, 667 series 60 FD Table 2 Mounting bracket for single acting actuator (8)(9) Mounting bracket for pneumatic actuators Code |