【DO!BOOK・ページリンク】 cv-07 64 / 138 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-AVP200-0100 - 7 - Note) *7 For the double acting actuator, a reversing relay unit is required. *14 If the valve body is for VFR (FloWing) or a butterfly valve, for the mounting bracket requirement consult to our sales. *15 Select the option with the restoration feedback lever, if GOM manufactured before April, 1998. Select the option ‘8’ (Accessory bracket for GOM actuator - User the case of existing GOP) if the existing control valve assembled with GOP and the accessories such as the Lock-up valves and solenoid valves. *16 Confirm that boss’s pitch of the actuator side is 69 mm, if it is required to assemble the mounting bracket to the actuator. Table 3 Mounting bracket for double acting actuator (8)(9) Mounting bracket for pneumatic actuators Code VP5, 6 *7 Y1 SLOP560, 1000, 1000X *7 *14 Y2 SLOP1500, 1500X *7 *14 Y3 DAP560, 1000, 1000X *7 *14 Y4 DAP560, 1500, 1500X *7 *14 Y5 GOM44L, 44LM (Springless horizontal) *7 G1 GOM410L, 410LM (Springless horizontal) *7 G2 GOM64L, 64LM (Springless horizontal) *7 G3 GOM66L, 66LM (Springless horizontal) *7 G4 GOM610L, 610LM (Springless horizontal) *7 G5 GOM84L, 84LM (Springless horizontal) *7 G6 GOM86L, 86LM (Springless horizontal) *7 G7 GOM810L, 810LM (Springless horizontal) *7 G8 GOM1210L, 1210LM (Springless horizontal) *7 GT GOM1510L, 1510LM (Springless horizontal) *7 GU GOM44L, 44LM (Springless horizontal) with restoration feedback lever *7 *15 GE GOM410L, 410LM (Springless horizontal) with restoration feedback lever *7 *15 GF GOM64L, 64LM (Springless horizontal) with restoration feedback lever *7 *15 GG GOM66L, 66LM (Springless horizontal) with restoration feedback lever *7 *15 GH GOM610L, 610LM (Springless horizontal) with restoration feedback lever *7 *15 GJ GOM84L, GOM84LM (Springless horizontal) with restoration feedback lever *7 *15 GK GOM86L, GOM86LM (Springless horizontal) with restoration feedback lever *7 *15 GL GOM810L, GOM810LM (Springless horizontal) with restoration feedback lever *7 *15 GM GOM1210L, GOM1210LM (Springless horizontal) with restoration feedback lever *7 *15 GN GOM1510L, GOM1510LM (Springless horizontal) with restoration feedback lever *7 *15 GP GOM84LM (Springless vertical) *7 GB GOM124LM (Springless vertical) *7 GC Nihon Koso 6300 series 63A2, AT series AT20 *7 T2 Nihon Koso 6300 series 63A3, B2, BA, B3, BB, B5, AT series AT-30, 200, 250, 300, 350, 500 *7 T3 Nihon Koso 6300 series 63A4, A5, A6, AT series AT40, AT50, AT60 *7 T4 Nihon Koso 6300 series AT series AT25 *7 T5 Nihon Koso TC-500 series TC-520W *7 *16 TP Nihon Koso TC-700 series TC-713W *7 TS Pentare Valve and Control Japan AK05, AK09, AK12, AK15 *7 KA Pentare Valve and Control Japan AG06, AGN06 *7 KG Pentare Valve and Control Japan AG09, AGN09 *7 KH Pentare Valve and Control Japan AG13, AGN13 *7 KJ Pentare Valve and Control Japan AW13 *7 KV Pentare Valve and Control Japan AW17 *7 KW KITZ B series BS-2, BSW-2, B-2 *7 B2 KITZ B series BS-3, BSW-3, B-3 *7 B3 KITZ B series BS-4, BSW-4, B-4 *7 B4 KITZ B series BS-5, BSW-5, B-5 *7 B5 KITZ B series BS-6, BSW-6, B-6 *7 B6 Tomoe Valve Z series Z-06, 08, 11, 13 *7 EA Tomoe Valve T-matic 3I-1, 2, 3, 4 *7 E3 NELES BC series BC/BIC11 *7 NB Table 4 Standard travel range and accuracy Actuator Travel (mm) Accuracy [% F.S.] PSA1, 2 14.3, 20, 25 1 PSA3, 4 20, 38 1 HA1 6, 8, 10 3 14.3, 25 1 HA2 10 3 14.3, 25, 38 1 HA3 14.3 3 25, 38, 50 1 HA4 14.3 3 25, 38, 50, 75 1 VA5 25, 37.5, 50, 75, 100 1 VA6 PSA6, 7 14.3 3 25, 37.5, 50, 75, 100 1 HK1 PSK1 10 3 19 1 Table 3 Mounting bracket for double acting actuator (8)(9) Mounting bracket for pneumatic actuators Code 7 5 |