yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz cv-07@@@71 / 138 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-AVP100-0100 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS Applicable actuator . Single acting actuator . Linear and rotary motion actuator Approvals NEPSI Intrinsically safe approval for model AVP100 Ex ia IIC T4-T6 Ga T4 at -40‹C to +60‹C T5 at -40‹C to +60‹C T6 at -40‹C to +40‹C The barriers should be NEPSI certified types and comply with the following condition as follows. Vi=30V, Ii=95mA, Pi=0.66W, Ci=6nF, Li=0.2mH NEPSI Intrinsically safe approval for model AVP102 Ex ia IIC T4-T6 Ga T4 at -40‹C to +60‹C T5 at -40‹C to +60‹C T6 at -40‹C to +40‹C The barriers should be NEPSI certified types and comply with the following condition as follows. Ui=30V, Ii=100mA, Pi=1.0W, Ci=0.015ƒÊF, Li=0.2mH The circuit shall be considered to be connected to ground from a safety point of view. Control signal input 4-20 mA DC (Split Range Configurable-4mA span Min.) Input resistance Model AVP100: 300 ƒ¶ max./ 20 mA DC Model AVP102: 600 ƒ¶ max./ 20 mA DC Output characteristics . Linear, Equal percentage, Quick opening . Custom user characteristics (16 points) Stem travel range Feedback lever Angle } 4‹ to } 20‹ Valve stem rotation 90‹ max. (rotary motion actuator) Bypass operation Auto / Manual switch (For single acting actuator only) Air supply pressure 140 to 700 kPa (1.4 to 7.0 kgf/cm2) Air consumption 4 ..(N)/minutes maximum at 140 kPa (1.4 kgf/cm2) 5 ..(N)/minutes maximum at 280 kPa (2.8 kgf/cm2) 6 ..(N)/minutes maximum at 500 kPa (5.0 kgf/cm2) Maximum air deliver flowrate 110L(N)/minutes at 140 kPa (1.4 kgf/cm2) Lightning protection Peak value of voltage surge: 12 kV Peak value of current surge: 1000A Vibration tolerance 2G (5 to 400 Hz) with standard mounting kit on Azbil Corporationfs HA actuator Ambient temperature limits -40‹C to 80‹C for general model NEPSI Intrinsically safe: -20‹C to 60‹C Ambient humidity limits 10% to 90% RH Configuration tools Model CFS100 (Field Communication Software CommStaff) PERFORMANCE SPECIFICATIONS Accuracy For 8 mA < input signal span < 16 mA } 1% F.S. (} 2.5% with custom output characteristics) For 4 mA < input signal span < 8 mA, } 1.5% F.S. PHYSICAL SPECIFICATIONS Enclosure classification IEC529 IP66, NEMA Type 4X equivalent Finish Baked acrylic Color Dark blue Material Body: Aluminum casting Pilot relay cover: PBT Weight Positioner: 1.7 kg INSTALLATION Air connections 1/4NPT internal thread Electrical connections 1/2NPT internal thread Conditions of supply air Particles Maximum diameter 3 ƒÊm Oil mist None acceptable Dew point 10‹C below ambient temperature Specifications for instrument air (JIS C1805-1 (2006)) Particles Maximum diameter 3 ƒÊm Oil mist Less than 1 ppm at mass Humidity of the air supply The dew point should be at least 10‹C lower than the temperature of this device. To meet the above specifications for instrument air, install the air purification devices listed in Table 1 properly in the specified installation location. Table 1 Examples of air purification devices Installation location Air purification device SMC Corp. CKD Corp. Compressor outlet or main line Line filter AFF Series AF Series Mist separator AM Series Terminal device Air combination AW30 M3000 (S type) |