yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz cv-07@@@75 / 138 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-SVX100-0100 Azbil Corporation - 2 - China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. FUNCTIONAL SPECIFICATIONS Control signal input 4-20 mA DC Input resistance Approx. 300....../ 20 mA DC: Model SVX100 (voltage between terminals 6V DC) Approx. 600 .. / 20 mA DC: Model SVX102 (voltage between terminals 12V DC) Approvals KEMA/ATEX Intrinsically safe approval (Model SVX102 only) II 1 G Ex ia IIC T4 Certificate No. KEMA 04ATEX1176 X The barriers should be ATEX certified types and comply with the following conditions as follows. Input circuit (terminals I IN) Ui=29V, Ii=95mA (resistively limited), Pi=690mW, Ci=10nF, Li=220..H From the safety point of view the supply/input circuit shall be considered to be connected to earth. FM Intrinsically safe approval (Model SVX102 only) Intrinsically safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F and G, T4 Ta=80‹C Intrinsically safe for Class I, Zone 0, AEx ia IIC T4 Nonincendive for Class I, Division 2, Groups A, B, C and D, T4 Suitable for Class II, III, Division 2, Groups F and G, T4 The barriers should be FM approved types and comply with the following conditions as follows. Input circuit: Vmax=30V, Imax=100mA, Pi=1W, Ci=15nF, Li=0.22mH Installation should comply with NEC. Output characteristics . Linear, Equal percentage, Quick opening . Custom user characteristics (16 points). Bypass operation Auto/Manual switch (For single acting actuator only) Air supply pressure 140 to 700 kPa (20 to 100 psi) Air consumption At stable output: 50% 10 l/min.(N) maximum at 400 kPa (60 psi) Maximum delivered air flowrate 250 l/min.(N) at 400 kPa (60 psi) Output balanced pressure 55 } 5% Lightning protection Peak value of voltage surge: 12 kV Peak value of current surge: 1000A Vibration tolerance 2 G (5 to 400 Hz) (with standard mounting kit on Azbil Corporation's HA actuator) Feedback lever angle } 4o to } 20o Ambient temperature limits -40‹C to 80‹C for general model KEMA/ATEX Intrinsically safe: -40‹C to 60‹C FM Intrinsically safe: -40‹C to 80‹C Ambient humidity limits 10% to 90% RH Configuration tools Model CFN100 (Smart Field Communicator CommPad) HART communication model 375 (According to need, please update a software and device description files.) CE conformity Electromagnetic compatibility EN 61326-1: 2006 (CE marking) PERFORMANCE SPECIFICATIONS Accuracy } 1.0% F.S. (} 2.5% F.S. with custom output characteristics) Turning range 50‹ to 90‹ PHYSICAL SPECIFICATIONS Enclosure rating JISC 0920 watertight NEMA type 4X IP66 FM Finish Baked acrylic Color Dark blue Material Cast aluminum Weight Without pressure gauge : 1.8 kg With pressure gauge : 2.2 kg |