【DO!BOOK・ページリンク】 cv-08 5 / 52 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-PVS200-0001 2.3 Auto-setup PLUG-IN Valstaff ’s auto-setup function automatically adjusts the positioner. Th e behavior of a control valve during auto-setup can be monitored during the error-checking portion of the automatic adjustment process. Also, the stroke time and hysteresis data collected during auto-setup can be compared with the past test data. Th is comparison provides an easy way to judge deterioration and the occurrence of abnormalities in the control valve. Figure 3. Auto-setup Screen 3. System Confi guration PLUG-IN Valstaff works in conjunction with the InnovativeField Organizer device management system made by Azbil Corporation or with the PRMR (Plant Resource Manager) made by Yokogawa Electric Corporation. 3.1 With Advanced-PS (TDCS3000) By operating PLUG-IN Valstaff on IFO, it is possible to manage control valves with a HART communication-compatible Smart Valve Positioner AVPx02. For details on system confi guration, refer to the spec sheet for IFO (SS2-IFO200-0001). HG A-MC PM100 PM-EX NIM EIM LCN network 4.20 mA PLUG-IN InnovativeField Organizer Device communication network (Ethernet) Input/output modules that comply with HART communication base unit format Figure 4. PLUG-IN Valstaff Confi guration for Advanced-PS/TDCS3000 3.2 With Harmonas-DEO R410 (Future release) By operating PLUG-IN Valstaff on IFO, it is possible to manage control valves with a Smart Valve Positioner AVPx02, AVPx03 by using HART communication or FOUNDATION fi eldbus. For details on system confi guration, refer to the spec sheet for IFO (SS2-IFO200-0001). In addition, if a device alert that was detected by PLUG-IN Valstaff is one that should be forwarded to an operator, it can be sent to operator stations (DOSS, DOSS_H, HSS, HSS_H, TSS) as an event. DOFC FOUNDATION fieldbus PLUG-IN X-BUS HC DOPC DOPC II DOPC III 4.20mA Device communication network (Ethernet) Input/output modules that comply with HART communication base unit format InnovativeField Organizer DEO control network Figure 5. PLUG-IN Valstaff Confi guration for Industrial-DEO/Harmonas R410 3.3 With Harmonas-DEO R400 or earlier By operating PLUG-IN Valstaff on IFO, it is possible to manage control valves with a Smart Valve Positioner by using HART communication. For details on system confi guration, refer to the spec sheet for IFO (SS2-IFO200-0001). X-BUS HC DOSS DOSS DOPC DOPC II DOPC III 4.20mA PLUG-IN Device communication network (Ethernet) Input/output modules that comply with HART communication base unit format InnovativeField Organizer DEO control network Figure 6. PLUG-IN Valstaff Confi guration for Industrial-DEO/ Harmonas R400 or earlier 3.4 IFO system confi guration which is independent from DCS Th e PLUG-IN Valstaff can be used in conjunction with IFO independent from DCS by using HUN (HART Network Unit ). In this case, PLUG-IN Valstaff can manage control valves with HART communication-compatible Smart Valve Positioner AVPx02. For details on system confi guration, refer to the spec sheet for IFO (SS2-IFO200-0001). 2 |