Azbil Corporation No. SS2-GTX00R-0100 - 15 - Model GTX40R (for regular type / high-temperature service / oxygen service) (For option gM5h, 0.1mm thickness diaphragm) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 3 inches (80 mm) Model GTX35R (for regular type / high-temperature service / oxygen service) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 2 inches (50 mm) Extended diaphragm 3 inches (80 mm) Model GTX35R (for regular type / oxygen service), (capillary length up to 3 m) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 1.5 inch (40 mm), 3/4 inches (20 mm), 1/2 inches (15 mm) Flange type code g1, 3h *3: Within a range of URV > 0 and LRV > 0 *4: Reference accuracy at calibrated condition. Reference accuracy (*3)(*4) } 0.4% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (0.1+ 0.3~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (*3) (Range from -5 to +55 oC) Combined shift } 2.84% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (1.52 + 1.32 ~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.06 + 0.94 ~ )% ƒÔ: kPa Combined shift } (0.06 + 1.44 ~ )% ƒÔ: kPa Reference accuracy (*4) } 0.2% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.05 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 0.88% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.55 + 0.33 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.03 + 1.44 ~ )% ƒÔ: kPa Combined shift } 1.97% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.03 + 1.94 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.3% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.15 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 0.88% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.55 + 0.33 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.03 + 1.44~ )% ƒÔ: kPa Combined shift } 1.97% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.03 + 1.94 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) 210 ƒÔ -------- 210 ƒÔ -------- 700 ƒÔ -------- 700 ƒÔ -------- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 1 6 |