Azbil Corporation No. SS2-GTX00R-0100 - 21 - Model GTX40R (for high temperature and vacuum / high temperature and high vacuum) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 2 inches (50 mm), 1.5 inch (40 mm) Model GTX35R (for regular type / high temperature service) Material of wetted parts: 316 SST Flange size: Flush diaphragm 3/4 inches (20 mm), 1/2 inch (15 mm) Flange type code g6h Model GTX35R (for regular type / high temperature service) Material of wetted parts: 316 SST Flange size: Flush diaphragm 3/4 inches (20 mm), 1/2 inch (15 mm) Flange type code g5h *3: Within a range of URV > 0 and LRV > 0. *4: Reference accuracy at calibrated condition. Reference accuracy (*3)(*4) } 0.2% (For x > 210 kPa (2.1 kgf/cm2)) } (0.05 + 0.15 ~ )% (For x < 210 kPa (2.1 kgf/cm2)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (*3) (Range from -5 to +55 oC) Combined shift } 3.0% (For x > 210 kPa (2.1 kgf/cm2)) } (2.2+ 0.8 ~ )% (For x < 210 kPa (2.1 kgf/cm2)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.75 ~ )% x: kPa Combined shift } (1.0 ~ )% x: kPa Reference accuracy (*4) } 0.2% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.05 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift }0.77% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.38+ 0.39 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 1.23% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.23~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 1.65% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.65 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.2% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.05 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift }0.81% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.38+ 0.43 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 1.47% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.47~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 1.97% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.97~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) 210 ƒÔ -------- 210 ƒÔ -------- 700 ƒÔ -------- 700 ƒÔ -------- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 1 6 |