No. SS2-GTX00U-0100 Azbil Corporation - 12 - Reference accuracy Shown for each item are the percentage ratio for ƒÔ (kPa), which is the greatest value of either the upper range value (URV)*1, the lower range value (LRV)*2 or the span. Model GTX35U (for regular type / high-temperature / oxygen service) Material of wetted parts: 316 SST (Diaphragm; 316L SST), 316L SST Flange size: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm) Model GTX35U (for regular type / high-temperature / oxygen / chlorine service) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 3 inches (80 mm) Model GTX35U (for regular type and high-temperature / oxygen service) (For option gM5h, 0.1mm thickness diaphragm) Material of wetted parts: 316 SST (Diaphragm; 316L SST), 316L SST Flange size: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm) Model GTX60U (for regular type / high-temperature / oxygen service) Material of wetted parts: 316 SST (Diaphragm; 316L SST), 316L SST Flange size: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm) *1: URV denotes the process value for 100% (20mA DC) output *2: LRV denotes the process value for 0% (4mA DC) output. *3: Within a range of URV > 0 and LRV > 0. *4: Reference accuracy at calibrated condition. Reference accuracy(*4) } 0.2% (For ƒÔ > 12.5 kPa {1250 mmH2O}) % (For ƒÔ < 12.5 kPa {1250 mmH2O}) Ambient Temperature effect (Shift from the set range) Change of 30oC (Range from -5 to 55oC) Combined shift: (including zero and span shifts) } 1.3% (For ƒÔ > 25 kPa {2500 mmH2O}) % (For ƒÔ < 25 kPa {2500 mmH2O}) Reference accuracy (*3)(*4) } 0.3% (For ƒÔ > 12.5 kPa {1250 mmH2O}) % (For ƒÔ < 12.5 kPa {1250 mmH2O}) Ambient Temperature effect (Shift from the set range) Change of 30oC (*3) (Range from -5 to 55oC) Combined shift: } 4.5% (For ƒÔ > 25 kPa {2500 mmH2O}) % (For ƒÔ < 25 kPa {2500 mmH2O}) Reference accuracy(*4) } 0.4% (For ƒÔ > 12.5 kPa {1250 mmH2O}) % (For ƒÔ < 12.5 kPa {1250 mmH2O}) Ambient Temperature effect (Shift from the set range) Change of 30oC (Range from -5 to 55oC) Combined shift: (including zero and span shifts) } 5.2% (For ƒÔ > 25 kPa {2500 mmH2O}) % (For ƒÔ < 25 kPa {2500 mmH2O}) Reference accuracy (*4) } 0.2% (For ƒÔ > 350 kPa {3.5 kgf/cm2}) % (For ƒÔ < 350 kPa {3.5 kgf/cm2}) Ambient Temperature effect (Shift from the set range) Change of 30oC (*3) (Range from -5 to 55oC) Combined shift: } 0.57% (For ƒÔ > 350 kPa {3.5 kgf/cm2}) % (For ƒÔ < 350 kPa {3.5 kgf/cm2}) 0.05 + 0.15 12.5 ƒÔ .. ~ ----------.. }.. .. 0.8 + 0.5 25 ƒÔ .. ~ -----.. }.. .. 0.15 + 0.15 12.5 ƒÔ .. ~ ----------.. }.. .. 1.5 + 3.0 25 ƒÔ .. ~ -----.. }.. .. 0.1 + 0.3 12.5 ƒÔ .. ~ ----------.. }.. .. 3.2 + 2.0 25 ƒÔ .. ~ -----.. }.. .. 0.05 0.15 350 ƒÔ .. + ~ --------.. }.. .. 0.19 0.38 350 ƒÔ .. + ~ --------.. }.. .. |