【DO!BOOK・ページリンク】 fi-01 148 / 226 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-GTX00U-0100 - 19 - Model GTX35U(Remote-sealed type for standard gauge pressure) Model GTX60U/GTX71U(Remote-sealed type for high gauge pressure) Extended 4 inches flange type for regular/ high temperature/ oxygen/ chlorine service Model No.:GTX_ _U-Selection I (I II III IV V VI VII VIII IX) Selection II - Option *1 In case Fill Fluid: For high-temperature service and Flange rating: ANSI300 and wetted parts material: 316L SST, Extension length of Flange 250/300mm are not available. *2 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. *3 In case Fill Fluid: For high-temperature service, not applicable for the combination with wetted parts material ”316L SST” and Flange Type “JIS 30K”. *4 In case Fill Fluid: Regular type or For oxygen service and Flange rating: JIS30K and wetted parts material:316L SST, Extended length of Flange 150/200/250/300mm are not available. Basic Model No. Measuring span 2.5 to 100kPa (250 to 10,160mmH20) GTX35U Extended flange type 4 inches 35 to 3500kPa (0.35 to 35kgf/cm2) GTX60U (100mm) 0.7 to 10MPa (7 to 102kgf/cm2) GTX71U Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication) *2 D II Fill fluid Regular type (Silicone oil) *4 A For high temperature service (Silicone oil) *1 *3 B For oxygen service (Fluorine oil) *4 H III Wetted parts material 316 SST (Diaphragm:316L SST) A 316L SST *1 *3 *4 D IV Flange rating ANSI150 A1 ANSI300 *1 A2 JIS10K J1 JIS20K J3 JIS30K *3 *4 J4 JPI150 P1 JPI300*1 P2 V Flange size 4in./100A G VI Flange type Extended Length 50mm B Extended Length 100mm C Extended Length 150mm *4 D Extended Length 200mm *4 E Extended Length 250mm *1 *4 F Extended Length 300mm *1 *4 G VII Flange material/ bolt and nut material Flange Bolt and nut 304 SST 304 SST A 304 SST 630 SST C 304 SST Carbon steel D 316 SST 304 SST E 316 SST 630 SST G 316 SST Carbon steel H 316L SST 304 SST J 316L SST 630 SST L 316L SST Carbon steel M VIII Gasket face finish None Standard JISRa3.2(12.5S) A IX Capillary length 2m 02 3m 03 4m 04 5m 05 6m 06 7m 07 8m 08 9m 09 10m 10 2m (with Olefin Cover) A2 3m (with Olefin Cover) A3 4m (with Olefin Cover) A4 5m (with Olefin Cover) A5 6m (with Olefin Cover) A6 7m (with Olefin Cover) A7 8m (with Olefin Cover) A8 9m (with Olefin Cover) A9 10m (with Olefin Cover) A0 1 7 |