yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@168 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
Azbil Corporation No. SS2-GTX00S-0100 - 3 - IECEx Flameproof and Dust Certifications Certificate No. IECEx KEM 08.0001 Ga/Gb Ex d IIC T6 Tprocess=85‹C -30‹C < Tamb < +75‹C IP66/67 Ga/Gb Ex d IIC T5 Tprocess=100‹C -30‹C < Tamb < +80‹C IP66/67 Ga/Gb Ex d IIC T4 Tprocess=110‹C -30‹C < Tamb < +80‹C IP66/67 Ex tD A21 IP66/67 T85 Tprocess=85‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T100 Tprocess=100‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T110 Tprocess=110‹C -30‹C < Tamb < +75‹C Caution - Use supply wires suitable for 5‹C above surrounding ambient IECEx Intrinsic safety and Dust Certifications IECEx KEM 07.0058X Zone 0 Ex ia IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 mA, Pi = 1 W, Ci = 5 nF, Li = 0.5 mH Ex iaD 20 IP66 / 67 T105 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IECEx Type n and Dust Certifications IECEx KEM 07.0058X Ex nL IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nF, Li = 0.5 mH Ex tD A21 IP66 / 67 T85 TPROCESS = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex tD A21 IP66 / 67 T100 TPROCESS = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex tD A21 IP66 / 67 T110 TPROCESS = 110 ‹C -30 ‹C < Tamb < +80 ‹C KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex d II C T5 Tprocess = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex d II C T4 Tprocess = 110 ‹C -30 ‹C < Tamb < +80 ‹C EMC Conformity 89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic Compatibility (EMC) Directive Measuring span / Setting range / Working pressure range Supply voltage and load resistance 17.9 to 42V DC. Reverse polarity protection is standard. A load resistance of 250 .. or more is necessary between loops. See Figure 2. Figure 2 Supply voltage vs. load resistance characteristics Note) For communication with HART communicator, a load resistance of 250 .. or more is necessary. Output Analog output (4 to 20 mA DC) with DE protocol Analog output (4 to 20 mA DC) with HART protocol Digital output (DE protocol) Output signal 3.6 to 21.6 mA 3.8 to 20.5 mA (NAMUR NE43 compliant) Failure Alarm Upper: 21.6 mA or more Lower: 3.6 mA or less Measuring span Setting range Working pressure range Overload resistant value GTX 30S 4 to 104 kPa abs. {30 to 780 mmHg abs.} 0 to 104 kPa abs. {0 to 780 mmHg abs.} 0.13 to 104 kPa abs. 300 kPa abs. {3.0 kgf/cm2} GTX 60S 35 to 3500 kPa abs. {0.35 to 35 kgf/cm2 abs.} 0 to 3500 kPa abs. {0 to 35 kgf/cm2 abs.} Up to flange rating of the setting range, which is lower. 5250 kPa abs. {52.5 kgf/cm2} b. For high temperature and vacuum, c. For high temperature and high vacuum Figure 1 Working pressure temperature of wetted parts section (For high temperature and vacuum / high temperature and high vacuum) -40 0 40 100 200 300 -5 280 b c 10 250 13 101.3 0.6 0.13 0.013 Temperature of wetted parts ( C) Working pressure (kPa abs.) 1.0 1345 1482 Load resistance (W) Supply voltage - 12.5 0.0219 245 0 17.9 42 45 Load resistance (ƒ¶) Supply voltage (V DC) Operating Range = Operative limit 12.5 1 8 |