【DO!BOOK・ページリンク】 fi-01 169 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00S-0100 Azbil Corporation - 4 - Ambient temperature limits / Temperature ranges of wetted parts Note *1. See the working pressures and temperatures of the wetted parts section in Figure 1. *2. Ambient temperatures of the transmitter itself *3. Approximate values at the temperature of 25°C *4. Note that if the operating temperature falls below the lower limit of the normal operating range, the response of the transmitter becomes slower. Ambient humidity limits 5 to 100% RH Stability against supply voltage change ± 0.005% FS/V Response time Approx. 400 ms (ref. value, with 5 m of ordinary capillaries, at room temp.) Damping time Selectable from 0 to 32 sec. in ten stages Lightning protection Applicable Standards; IEC 61000-4-5 Peak value of current surge(80/20....sec...: 6000A Indicator The digital LCD indicator (optional) indicates engineering units and can be set freely between -99999 and 99999 (5 digits). For meter calibration, specify the following items when placing your order . Meter calibration range . Meter calibration unit . Linear / Square-root for meter indication. Various kinds of data can be set using the communicator. Bolts and nuts materials (for fastening meter body cover) Carbon steel (SNB7), 304 SST, 630 SST Paint Standard Corrosion-resistant paint (Baked acrylic paint) Corrosion-proof finish Corrosion-proof paint (Baked urethane paint), fungusproof finish OPTIONAL SPECIFICATIONS Oil free finish The transmitter is shipped with oil-free wetted parts. External zero/span adjustment function The transmitter can be easily zero/span adjusted in the field. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to SI units We deliver transmitters set to any SI units as specified. Safety Transmitter Select this option to be used as a component of Safety Instrumented System (SIS). AT9000 is complied with IEC61508, certified according to Safety Integrity Level2 (SIL-2) Alarm Output (contact output) Contact output is prepared as alarm output when alarm (Output Alarm/Sensor Temp. Alarm) condition is detected. It can be set to Normally Open. (When alarm is detected, Contact ON). Custom calibration Calibrate for the specified pressure range at the factory. PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for high-temperature vacuum, and high temperature high-vacuum models For specific gravity, refer to “Ambient temperature limits / Temperature ranges of wetted parts” on page 4 Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) Meter body cover 304 SST For Wetted parts 316 SST (316L SST for diaphragm only) 316L SST Flange materials 304 SST, 316 SST, 316L SST Weight Approx. 13.5 kg (GTX30S) (Including ANSI 150# - 3 inches flange and capillary 5 m long) Temperature Range (°C) *1 *4 High-temp. vacuum models High-temp. high-vacuum models Wetted parts section Normal operating range -5 to 280 10 to 300 Operative limit range -10 to 310 -10 to 310 Ambient temperature *2 Normal operating range -5 to 55 10 to 55 Operative limit range -10 to 60 -10 to 60 Specific gravity of fill fluid *3 1.07 1.09 |