yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@203 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-PTG300-0100 Azbil Corporation - 18 - Flange type (1/2 inch, 1 inch, 2 inches) Measuring Span / Setting Range / Max. Working Pressure Accuracy / Temperature effect Model PTG7_ F- _3 Model PTG7_ F- _4 Model PTG7_ F- _5 Model PTG7_ F- _6 Note) *1: Within a range of URV > 0 and LRV > 0 Ambient temperature limits Normal operating range Transportation and storage temperature -30 to +80‹C Temperature ranges of wetted parts 150‹C for 60 minutes during steam cleaning for water and dust proof model Ambient humidity limits 5 to 100% RH Materials Fill fluid . Silicone oil . Propylene glycol Wetted parts Diaphragm SUS316L Others SUS316 Flange parts SUS304 Case Aluminum alloy Weight JIS10K 50mm type : Approx. 4.2 kg JIS10K 15mm type : Approx. 2 kg Process connection . JIS10K 15 mm, 50 mm . JIS20K 15 mm, 25 mm . JIS30K 15 mm, 50 mm For other specification, please refer to COMMON SPECIFICATIONS. Model Number Measuring span Setting Range Max. Working Pressure Process Connection PTG7_F - _3 2.0 to 100 kPa -100 to +100 kPa 200 kPa 2 inches (50 mm), 1inch (25 mm), 1/2 inch (15 mm) PTG7_F - _4 40 to 400 kPa -100 to +400 kPa 800 kPa PTG7_F - _5 0.2 to 2 MPa -0.1 to +2 MPa 4 MPa or flange rating PTG7_F - _6 1 to 10 MPa -0.1 to +10 MPa 20 MPa or flange rating Accuracy *1 } 0.5% F.S. (100 kPa > X > 20 kPa) } (0.5 ~ 2 0 / X)% F.S. (20 kPa > X > 2 kPa) Zero temperature effect per 30‹C *1 1 inches (25mm) } (4.5 ~ 40 / X +0.35)% 2 inches (50 mm) 1/2 inch (15 mm) } (10.0 ~ 40 / X +0.35)% Accuracy *1 } 0.5% F.S. (400 kPa > X > 80 kPa) } (0.5 ~ 80 / X)% F.S. (80 kPa > X> 40 kPa) Zero temperature effect per 30‹C *1 1 inches (25mm) } (2.4 ~ 80 / X +0.35)% 2 inches (50 mm) 1/2 inch (15 mm) } (7.1 ~ 80 / X +0.35)% Accuracy *1 } 0.5%F.S. (2MPa>X>0.4MPa) } (0.5~0.4 / X)%F.S. (0.4MPa >X>0.2MPa) Zero temperature effect per 30‹C *1 1 inches (25mm) } (0.8~0.4 / X +0.35)% 2 inches (50 mm) 1/2 inch (15 mm) } (1.4~0.4 / X +0.35)% Accuracy *1 } 0.5% F.S. (10.0 MPa > X > 2.0 MPa) } (0.5 ~ 2.0 / X)% F.S. (2.0 MPa > X > 1.0 MPa) Zero temperature effect per 30‹C *1 1 inches (25mm) 2 inches (50 mm) } (0.5 ~ 2.0 / X +0.35)% 1/2 inch (15 mm) Fill fluid Water and dust proof FM Explosion proof FM Intrinsically safe KOSHA Flameproof NEPSI Flameproof (Ex d II CT4,5) ATEX Flameproof NEPSI Flameproof (Ex d IICT6) Silicone oil -20 to +70‹C -20 to +60‹C -20 to +40‹C Propylene glycol -10 to +70‹C -10 to +60‹C -10 to +40‹C Fill fluid Water and dust proof FM Explosion proof FM Intrinsically safe KOSHA Flameproof NEPSI Flameproof (Ex d II CT4) ATEX Flameproof NEPSI Flameproof (Ex d IICT5) NEPSI Flameproof (Ex d IICT6) Silicone oil -40 to +110‹C -20 to +110‹C -20 to +95‹C -20 to +80‹C Propylene glycol -10 to +110‹C -10 to +110‹C -10 to +95‹C -10 to +80‹C |