yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@217 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-PTG300-0100 Azbil Corporation - 32 - Ferrule with cooling tower (1.5S, 2S cap nut type) Measuring span/ Setting range/ Max. working pressure Accuracy / Temperature effect Model PTG7_ K- _3 Model PTG7_ K- _4 Model PTG7_ K- _5 Note) *1: Within a range of URV > 0 and LRV > 0 Ambient temperature limits Normal operating range Transportation and storage temperature -30 to +80‹C Temperature ranges of wetted parts Ambient humidity limits 5 to 100% RH Materials Fill fluid . Propylene glycol Wetted parts Diaphragm SUS316L Others SUS316 Case Aluminum alloy Weight . 1.5S: Approx. 1.6 kg . 2S: Approx. 1.9 kg Process connection . IDF 1.5S ferrule cap nut type . IDF 2S ferrule cap nut type For other specification, please refer to COMMON SPECIFICATIONS. Model Number Measuring span Setting Range Max. Working Pressure Process Connection PTG7_K - _3 2.0 to 100 kPa -100 to +100 kPa 200 kPa PTG7_K - _4 40 to 400 2S, 1.5S kPa -100 to +400 kPa 800 kPa or cap nut rating PTG7_K - _5 0.2 to 2 MPa -0.1 to +2 MPa 4 MPa or cap nut rating Accuracy *1 } 0.5% F.S. (100 kPa > X > 20 kPa) } (0.5 ~ 20 / X)% F.S. (20k Pa > X> 2 kPa) Zero temperature effect per 30‹C *1 2S (Cap nut type) } (2.5 ~ 40 / X +0.35)% 1.5S (Cap nut type) } (15.5 ~ 40 / X +0.35)% Accuracy *1 } 0.5% F.S. (400 kPa > X > 80 kPa) } (0.5 ~ 80 / X)% F.S. (80 kPa > X > 40 kPa) Zero temperature effect per 30‹C *1 2S (Cap nut type) } (1.4 ~ 80 / X +0.35)% 1.5S (Cap nut type) } (7.9 ~ 80 / X +0.35)% Accuracy *1 } 0.5% F.S. (2 MPa > X > 0.4 MPa) } (0.5 ~ 0.4 / X)% F.S. (0.4 MPa > X > 0.2 MPa) Zero temperature effect per 30‹C *1 2S (Cap nut type) } (0.6 ~ 0.4 / X +0.35)% 1.5S (Cap nut type) } (1.9 ~ 0.4 / X +0.35)% Water and dust proof FM Explosion proof FM Intrinsically safe KOSHA Flameproof NEPSI Flameproof (Ex d II CT4,5) ATEX Flameproof NEPSI Flameproof (Ex d IICT6) -10 to +70‹C -10 to +60‹C -10 to +40‹C Water and dust proof FM Explosion proof FM Intrinsically safe KOSHA Flameproof NEPSI Flameproof (Ex d II CT4) ATEX Flameproof NEPSI Flameproof (Ex d IICT5) NEPSI Flameproof (Ex d IICT6) -10 to +150‹C -10 to +110‹C -10 to +95‹C -10 to +80‹C |