Azbil Corporation No. SS2-GTX00A-0100 - 3 - IECEx Flameproof and Dust Certifications Certificate No. IECEx KEM 08.0001 Ga/Gb Ex d IIC T6 Tprocess=85‹C -30‹C < Tamb < +75‹C IP66/67 Ga/Gb Ex d IIC T5 Tprocess=100‹C -30‹C < Tamb < +80‹C IP66/67 Ga/Gb Ex d IIC T4 Tprocess=110‹C -30‹C < Tamb < +80‹C IP66/67 Ex tD A21 IP66/67 T85 Tprocess=85‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T100 Tprocess=100‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T110 Tprocess=110‹C -30‹C < Tamb < +75‹C Caution - Use supply wires suitable for 5‹C above surrounding ambient IECEx Intrinsic safety and Dust Certifications IECEx KEM 07.0058X Zone 0 Ex ia IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 mA, Pi= 1 W, Ci = 5 nF, Li = 0.5 mH Ex iaD 20 IP66 / 67 T105 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IECEx Type n and Dust Certifications IECEx KEM 07.0058X Ex nL IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nF, Li = 0.5 mH Ex tD A21 IP66 / 67 T85 TPROCESS = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex tD A21 IP66 / 67 T100 TPROCESS = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex tD A21 IP66 / 67 T110 TPROCESS = 110 ‹C -30 ‹C < Tamb < +80 ‹C KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex d II C T5 Tprocess = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex d II C T4 Tprocess = 110 ‹C -30 ‹C < Tamb < +80 ‹C EMC Conformity 89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic Compatibility (EMC) Directive Measuring span / Setting range / Working pressure range Note) With PVC wetted parts, the maximum working pressure is 1.5 MPa {15 kgf/cm2}. Figure 1 Working pressure and temperature of wetted parts section (for general purpose models) Figure 2 Working pressure and temperature of wetted parts section (for oxygen and chlorine service models) Supply voltage and load resistance 17.9 to 42V DC. Reverse polarity protection is standard. A load resistance of 250 ƒ¶ or more is necessary between loops. See Figure 3. Figure 3 Supply voltage vs. load resistance characteristics Note) For communication with HART communicator, a load resistance of 250 ƒ¶ or more is necessary. Measuring Span Setting Range Working Pressure Range Overload Resistant Value GTX 30A 4 to 104 kPa abs {30 to 780 mmHg abs} 0 to 104 kPa abs {0 to 780 mmHg abs} 0.01 to 104 kPa abs {0.1 to 780 mmHg abs} See Figure 1 300 kPa abs {3.0 kgf/cm2 abs} GTX 60A 35 to 3500 kPa abs {0.35 to 35 kgf/ cm2 abs} 0 to 3500kPa abs {0 to 35 kgf/cm2 abs} 0.01 to 3500 kPa abs {0.1 mmHg abs to 35 kgf/cm2 abs} See Figure 1 5250 kPa abs {52.5 kgf/cm2 abs} Temperature of wetted parts ( C) Working pressure P kPa abs {mmHg} -50-40 0 50 100 0.13 1.0 10.0 101.3 1000.0 0.013 {0.1} Normal operating range Operative limits SUS316 Other than SUS316 Operative limits 110 C 115 C 133.3 101.3 53 -40 -10 0 40 75 80 Normal operating range Working pressure P kPa {mmHg} Temperature of wetted parts ( C) Unusable range {1000} {760} {400} 1345 1482 Load resistance (W) Supply voltage - 12.5 0.0219 245 0 17.9 42 45 Load resistance (ƒ¶) Supply voltage (V DC) Operating Range = Operative limit 12.5 1 2