yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@5 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-GTX00D-0100 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS FM Explosionproof and Dust Approvals (Code F1) Explosionproof for Class I, Division 1, Groups A, B, C and D; Class I, Zone 1, AEx d IIC Dust-Ignitionproof for Class II, III, Division 1, Groups E, F and G T5 -40‹C < Tamb < +85‹C Hazardous locations Indoor / Outdoor Type 4X, IP67 Factory sealed, conduit seal not required for Division applications Caution - Use supply wires suitable for 5‹C above surrounding ambient FM Intrinsically safe Approval (Code F2) IS/I,II,III/1/ABCDEFG/T4; -40 ‹C < Tamb < +60 ‹C; 80395278, 80395279,80395280; Entity; TYPE 4X; IP67 I/0/ AEx ia/IIC/T4; -40 ‹C < Tamb < +60 ‹C;80395278, 80395279, 80395280; Entity; TYPE 4X;IP67 Entity Parameters: Vmax(Ui)=30 Volts, Imax(Ii)=100mA, Pi=1W, Ci=10nF, Li=0.5mH FM Nonincendive Approval (Code F5) NI/I/2/ABCD/T4; -40 ‹C < Tamb < +60 ‹C;80395494; NIFW; TYPE 4X; IP67 NI/I/2/IIC/T4; -40 ‹C < Tamb < +60 ‹C; 80395494; NIFW; TYPE 4X; IP67 S/II,III/1/EFG/T4; -40 ‹C < Tamb < +60 ‹C; 80395494;NIFW; TYPE 4X; P67 Nonincendive Field Wiring Parameters: Vmax(Ui)=30 Volts, Ci=10nF, Li=0.5mH Combination of F1, F2 and F5 (Code F6) ATEX Flameproof and Dust Certifications (Code A1) 0344 KEMA 08ATEX0004 II 1/2 G Ex d IIC T6 Tprocess=85‹C -30‹C < Tamb < +75‹C IP66/67 II 1/2 G Ex d IIC T5 Tprocess=100‹C -30‹C < Tamb < +80‹C IP66/67 II 1/2 G Ex d IIC T4 Tprocess=110‹C -30‹C < Tamb < +80‹C IP66/67 II 2 D Ex tD A21 IP66/67 T85 Tprocess=85‹C -30‹C < Tamb < +75‹C II 2 D Ex tD A21 IP66/67 T100 Tprocess=100‹C -30‹C < Tamb < +75‹C II 2 D Ex tD A21 IP66/67 T110 Tprocess=110‹C -30‹C < Tamb < +75‹C Caution - Use supply wires suitable for 5‹C above surrounding ambient ATEX Intrinsic safety and Dust Certifications (Code A2) 0344 KEMA 07ATEX0200 X II 1 G Ex ia IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 mA, Pi = 1 W, Ci = 5 nF, Li = 0.5 mH II 1 D Ex iaD 20 IP66 / 67 T105 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C ATEX Type n and Dust Certifications (Code A5) 0344 KEMA 07ATEX0200 X II 3 G Ex nL IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nF, Li = 0.5 mH II 2 D Ex tD A21 IP66 / 67 T85 TPROCESS = 85 ‹C -30 ‹C < Tamb < +75 ‹C II 2 D Ex tD A21 IP66 / 67 T100 TPROCESS = 100 ‹C -30 ‹C < Tamb < +80 ‹C II 2 D Ex tD A21 IP66 / 67 T110 TPROCESS = 110 ‹C -30 ‹C < Tamb < +80 ‹C NEPSI Flameproof and Dust Certifications (Code N1) Ex d IIC T6 DIP A21 TA 85‹C Tprocess=80‹C -40‹C < Tamb < +75‹C Ex d IIC T5 DIP A21 TA 100‹C Tprocess=95‹C -40‹C < Tamb < +80‹C Ex d IIC T4 DIP A21 TA 115‹C Tprocess=110‹C -40‹C < Tamb < +80‹C ENCLOSURE TYPE IP66/67 NEPSI Intrinsic Safety Certification (Code N2) Ex ia IIC T4 Tprocess=105‹C -40‹C < Tamb < +60‹C Enclosure IP66 / 67 Electrical Parameters: Ui=30V, Ii=100mA, Pi=1W, Ci=13nF, Li=0.5mH NEPSI Type n Certification (Code N5) Ex nL IIC T4 Tprocess=110‹C -40‹C < Tamb < +60‹C Enclosure IP66 / 67 Electrical Parameters: Ui=30V, Ii=100mA, Pi=1W, Ci=13nF, Li=0.5mH IECEx Flameproof and Dust Certifications (Code E1) Certificate No. IECEx KEM 08.0001 Ga/Gb Ex d IIC T6 Tprocess=85‹C -30‹C < Tamb < +75‹C IP66/67 Ga/Gb Ex d IIC T5 Tprocess=100‹C -30‹C < Tamb < +80‹C IP66/67 Ga/Gb Ex d IIC T4 Tprocess=110‹C -30‹C < Tamb < +80‹C IP66/67 Ex tD A21 IP66/67 T85 Tprocess=85‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T100 Tprocess=100‹C -30‹C < Tamb < +75‹C Ex tD A21 IP66/67 T110 Tprocess=110‹C -30‹C < Tamb < +75‹C Caution - Use supply wires suitable for 5‹C above surrounding ambient |