Azbil Corporation No. SS2-GTX00D-0100 - 3 - IECEx Intrinsic safety and Dust Certifications (Code E2) IECEx KEM 07.0058X Zone 0 Ex ia IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 mA, Pi = 1 W, Ci = 5 nF, Li = 0.5 mH Ex iaD 20 IP66 / 67 T105 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IECEx Type n and Dust Certifications (Code E5) IECEx KEM 07.0058X Ex nL IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nF, Li = 0.5 mH Ex tD A21 IP66 / 67 T85 TPROCESS = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex tD A21 IP66 / 67 T100 TPROCESS = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex tD A21 IP66 / 67 T110 TPROCESS = 110 ‹C -30 ‹C < Tamb < +80 ‹C KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex d II C T5 Tprocess = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex d II C T4 Tprocess = 110 ‹C -30 ‹C < Tamb < +80 ‹C EMC Conformity 89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic Compatibility (EMC) Directive PED Conformity (97/23EC) The maximum pressures applicable under the Sound Engineering Practice (SEP) section of the Pressure Equipment Directive depend on the type of fluid measured, as shown in the table below. Note) Group 1 comprises fluids defines as: explosive, extremely flammable, highly flammable, flammable, very toxic, toxic and oxidizing. Group 2 comprises all other fluids not refer to group 1 Any AT9000 model having a maximum working pressure that is higher than the pressure corresponding to its group does not conform to SEP. Models GTX32D, 42D, 72D and 82G conform to PED according to Module A. Measuring span / Setting range / Working pressure range Note) 1)With PVC wetted parts, the maximum working pressure is 1.5 MPa {15 kgf/cm2}. 2) With 304 SST SST bolts and nuts, the maximum working pressure is 10MPa {100 kgf/cm2}. 3) With 304 SST SST bolts and nuts, the maximum working pressure is 20 MPa {200 kgf/cm2}. Measured fluid Group * Pressure Applicable models Gas 1 200 bar (20 MPa) All models except GTX32D, 42D, 72D, 82G 2 1,000 bar (100 MPa) All models Liquid 1 500 bar (50 MPa) All models 2 1,000 bar (100 MPa) All models Model Measuring Span Measuring range Working Pressure Range GTX 15D 0.1 to 2 kPa {10 to 200 mmH2O} -1 to 1 kPa {-100 to 100 mmH2O} -70 to 210 kPa {-0.7 to 2.1 kgf/cm2} GTX 30D 0.5 to 100 kPa {50 to 10160 mmH2O} -100 to 100 kPa {-10160 to 10160 mmH2O} 2.0 kPa abs to 3.5 MPa {15 mmHg abs to 35 kgf/ cm2} *1 GTX 31D 0.5 to 100 kPa {50 to 10160 mmH2O} -100 to 100 kPa {-10160 to 10160 mmH2O} 2.0 kPa abs to 21 MPa {15 mmHg abs to 210 kgf/ cm2}*1, *2 (For vacuum pressure, see Figure 1, 2) GTX 32D 0.5 to 100 kPa {50 to 10160 mmH2O} -100 to 100 kPa {-10160 to 10160 mmH2O} 2.0 kPa abs to 42 MPa {15mmHg abs to 420 kgf/ cm2} *3 (For vacuum pressure, see Figure 1, 2) GTX 40D 35 to 700 kPa {0.35 to 7 kgf/cm2} -100 to 700 kPa {-1 to 7kgf/cm2} 2.0 kPa abs to 3.5 MPa {15 mmHg abs to 35 kgf/ cm2} *1 GTX 41D 35 to 700 kPa {0.35 to 7 kgf/cm2} -100 to 700 kPa {-1 to 7kgf/cm2} 2.0 kPa abs to 21 MPa {15 mmHg abs to 210 kgf/ cm2}*1, *2 (For vacuum pressure, see Figure 1, 2) GTX 42D 35 to 700 kPa {0.35 to 7 kgf/cm2} -100 to 700 kPa {-1 to 7kgf/cm2} 2.0 kPa abs to 42 MPa {15mmHg abs to 420 kgf/ cm2} *3 (For vacuum pressure, see Figure 1, 2) GTX 71D 0.25 to 14 MPa {2.5 to 140kgf/cm2} -0.1 to 14 MPa {-1 to 140 kgf/cm2} 2.0 kPa abs to 20 MPa {15 mmHg abs to 210 kgf/ cm2}*1, *2 (For vacuum pressure, see Figure 1, 2) GTX 72D 0.25 to 14 MPa {2.5 to 140 kgf/cm2} -0.1 to 14 MPa {-1 to 140 kgf/cm2} 2.0 kPa abs to 42 MPa {15mmHg abs to 420 kgf/ cm2} *3 (For vacuum pressure, see Figure 1, 2) 1 1 |