【DO!BOOK・ページリンク】 fi-01 95 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00R-0100 Azbil Corporation - 6 - Figure 5 Ambient temperature and temperature of wetted parts section (for general purpose models) [Flange diameter: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm) Extended diaphragm 3 inches (80 mm) / 2 inches (50 mm)] Note) When the fill liquid is for general purposes, make sure before using your transmitter that the conditions in both Figure 1, Figure 5 and Figure 6 are met. Figure 6 Ambient temperature and temperature of wetted parts section (for general purpose models) [Flange diameter: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm)] Figure 7 Ambient temperature and temperature of wetted parts section (for high temperature and vacuum 2, 3 m) [Flange diameter: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 8 Ambient temperature and temperature of wetted parts section (for high temperature and vacuum 4, 5 m) [Flange diameter: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 9 Ambient temperature and temperature of wetted parts section (for high temperature and high vacuum 2, 3 m) [Flange diameter: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 10 Ambient temperature and temperature of wetted parts section (for high temperature and high vacuum 4, 5 m) [Flange diameter: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Ambient humidity limits 5 to 100% RH Stability against supply voltage change ± 0.005% FS/V Response time Approx. 700 ms (ref. value, with 5 m of ordinary capillaries, at room temp.) Damping time Selectable from 0 to 32 sec. in ten stages Lightning protection Applicable Standards; IEC 61000-4-5 Peak value of current surge(80/20μ sec.): 6000 A Normal operating range Ambient temperature ( C) Temperature of wetted parts ( C) Operative limit range 100 80 75 72 68 50 -50 -40 100 110 150 180185 200 Ambient temperature ( C) Temperature of wetted parts ( C) 100 80 -50 -40 100 110 150 180185 200 Normal operating range Operative limit range 61 58 50 65 Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10-5 165180 280 310 33 27 55 -5 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10-5 100 125 280 310 30 27 55 -5 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10 10 230 240 280 310 47 43 55 10 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10 10 160 190 280 310 41 39 55 10 -10 Normal operating range Operative limit range |