No. SS2-KFK100-0100 -2 - SPECIFICATIONS Standard Specifications Item Specifications Detector Model No. Pressure element Measuring range Process connection Pressure limit Allowable overload Suppression (max.) Elevation (max.) 11 0-5 to 0-70 MPa {0-50 to 0-700 kgf/cm2} Welding nipple connection (13.6 x 50) -0.1 to +70 MPa {-1 to +700 kgf/cm2} -0.1, 75 MPa {-1, 750 kgf/cm2} 65 MPa {650 kgf/cm2} 12 0-1.25 to 0-25 MPa {0-12.5 to 0-250 kgf/cm2} -0.1 to +30 MPa {-1 to +300 kgf/cm2} -0.1, 32 MPa {-1, 320 kgf/cm2} 28.75 MPa {287.5 kgf/cm2} 13 0-0.35 to 0-7 MPa {0-3.5 to 0-70 kgf/cm2} -0.1 to +10.5 MPa {-1 to +105 kgf/cm2} -0.1, 14 MPa {-1, 140 kgf/cm2} 10.15 MPa {101.5 kgf/cm2} 14 Bourdon tube 0-0.175 to 0-3.5 MPa {0-1.75 to 0-35 kgf/cm2} -0.1 to +5.25 MPa {-1 to +52.5 kgf/cm2} -0.1, 7 MPa {-1, 70 kgf/cm2} 5.075 MPa {50.75 kgf/cm2} 15 0-35 to 0-686 MPa {0-0.35 to 0-7 kgf/cm2} -0.1 to +1.05 MPa {-1 to +10.5 kgf/cm2} -0.1, 1.4 MPa {-1, 14 kgf/cm2} 1.015 MPa {10.15 kgf/cm2} 16 0-10 to 0-196 kPa {0-0.1 to 0-2 kgf/cm2} -100 to +300 kPa {-1 to +3 kgf/cm2} -100, 400 kPa {-1, 4 kgf/cm2} -100 kPa {-1 kgf/cm2} 290 kPa {2.9 kgf/cm2} 17 0-3.4 to 0-66.6 kPa {0-25 to 0-500 mmHg} -66.6 to +66.6 kPa {-500 to +500 mmHg} -66.6, 400 kPa {-500 mmHg, 4 kgf/cm2} -66.6 kPa {-500 mm Hg} 63.2 kPa {475 mmHg} 18 Bellows 0-0.7 to 0-13.3 kPa {0-5 to 0-100 mmHg} -13.3 to +13.3 kPa {-100 to +100 mmHg} -13.3, 400 kPa {-100 mmHg, 4 kgf/cm2} -13.3 kPa {-100 mm Hg} 12.6 kPa {95mmHg} 25 0-35 to 0-686 kPa abs. {0-0.35 to 0-7 kgf/cm2} abs. 0 to 686 kPa abs. {0 to 7 kgf/cm2} abs. -1.4 MPa abs {14 kgf/cm2} abs. .. 653 kPa abs. {6.65 kgf/cm2} abs. 26 0-10 to 0-196 kPa abs. {0-0.1 to 0-2 kgf/cm2} abs. 0 to 196 kPa abs. {0 to 2 kgf/cm2} abs. 0.6 MPa abs. {6 kgf/cm2} abs. .. 186 kPa abs. {1.9 kgf/cm2} abs. 27 0-3.4 to 0-66.6 kPa abs. {0-25 to 0-500 mmHg} abs. 0 to 66.6 kPa abs. {0 to 500 mmHg} abs. 0.4 MPa abs. {4 kgf/cm2} abs. .. 63.2 kPa abs. {475 mmHg} abs. 28 Bellows (absolute pressure) 0-0.7 to 0-13.3 kPa abs. {0-5 to 0-100 mmHg} abs. Rc. or Rc. internal Thread .NPT or .NPT internal thread 0 to 13.3 kPa abs. {0 to 100 mmHg} abs. 0.4 MPa abs. {4 kgf/cm2} abs. .. 12.6 kPa abs. {95 mmHg} abs. 71 0-5 to 0-70 MPa {0-50 to 0-700 kgf/cm2} G1. external thread (34 button diaphragm) -0.05 to +70 MPa {-0.5 to +700 kgf/cm2} -0.05, 70 MPa {-0.5, 750 kgf/cm2} 65 MPa {650 kgf/cm2} 72 0-1.25 to 0-25 MPa {0-12.5 to 0-250 kgf/cm2} G1. external thread (34 button diaphragm) or 2 in. ANSI wafer -0.05 to +30 MPa {-0.5 to +300 kgf/cm2} -0.05, 32 MPa {-0.5, 320 kgf/cm2} 28.75 MPa {287.5 kgf/cm2} 73 0-0.35 to 0-7 MPa {0-3.5 to 0-70 kgf/cm2} 2 in. -ANSI wafer -0.05 to +10.5 MPa {-0.5 to +105 kgf/cm2} -0.05, 14 MPa {-0.5, 140 kgf/cm2} 10.15 MPa {101.5 kgf/cm2} 2 in. -ANSI wafer -0.05 to +5.25 MPa {-0.5 to +52.2 kgf/cm2} -0.05, 7 MPa {-0.5, 70 kgf/cm2} 5.075 MPa {50.75 kgf/cm2} 80 mm-JIS30K flush diaphragm 100 mm-JIS30K extended diaphragm -0.05 to +5.1 MPa {-0.5 to +51 kgf/cm2} -0.05, 5.1 MPa {-0.5, 51 kgf/cm2} 4.925 MPa {49.25 kgf/cm2} 74 0-0.175 to 0-3.5 MPa {0-1.75 to 0-35 kgf/cm2} 3 in. -ANSI300 flush diaphragm 4 in. -ANSI300 extended diaphragm -0.05 to +3.82 MPa {-0.5 to +37 kgf/cm2} -0.05, 3.82 MPa {-0.5, 37 kgf/cm2} -0.05 MPa {-0.5 kgf/cm2} 3.525 MPa {35.25 kgf/cm2} 80 mm-JIS10K flush diaphragm 100 mm-JIS10K extended diaphragm 75 0-35 to 0-686 kPa {0-0.35 to 0-7 kgf/cm2} 3 in. -ANSI150 flush diaphragm 4 in. -ANSI150 extended diaphragm -0.05 to +1.05 MPa {-0.5 to +10.5 kgf/cm2} -0.05, 1.4 MPa {-0.5, 14 kgf/cm2] 1.015 MPa {10.15 kgf/cm2} 80 mm-JIS10K flush diaphragm 100 mm-JIS10K extended diaphragm 76 Remote seal diaphragm 0-10 to 0-196 kPa {0-01 to 0-2 kgf/cm2} 3 in. -ANSI150 flush diaphragm 4 in. -ANSI150 extended diaphragm -0.05 to +0.3 MPa {-0.5 to +3 kgf/cm2} -0.05, 0.4 MPa {-0.5, 4 kgf/cm2} -0.05 MPa {-0.5 kgf/cm2} 0.29 MPa {2.9 kgf/cm2} Note 1) Elevation + Span .. Max. span. 2) Refer to the annexed table about Max. working pressure on Remote seal diaphragm. |