No. SS2-KFK100-0100 -4 - Item Specifications Function Model No. Measuring range KFKB 11/71 0-5 {0-50 to 0- less than 10 MPa to 0- less than 100 kgf/cm2} 0-10 {0-100 to 0-70 MPa to 0-700 kgf/cm2} 12/72 0-1.25 {0-12.5 to 0- less than 2.5 MPa to 0- less than 25 kgf/cm2} 0-2.5 {0-25 to 0-25 MPa to 0-250 kgf/cm2} 13/73 0-0.35 {0-3.5 to 0- less than 0.7 MPa to 0- less than 7 kgf/cm2} 0-0.7 {0-7 to 0-7 MPa to 0-70 kgf/cm2} 14/74 0-0.175 {0-1.75 to 0- less than 0.35 MPa to 0- less than 3.5 kgf/cm2} 0-0.35 {0-3.5 to 0-3.5 MPa to 0-35 kgf/cm2} 15/75 0-35 {0-0.35 to 0- less than 68.6 kPa to 0- less than 0.7 kgf/cm2} 0-68.6 {0-0.7 to 0-686 kPa to 0-7 kgf/cm2} Accuracy 16/76 0-10 {0-0.1 to 0- less than 19.6 kPa to 0- less than 0.2 kgf/cm2} 0-19.6 0-0.2 to 0-196 kPa to 0-2 kgf/cm2} 17 0-3.4 {0-25 to 0- less than 6.66 kPa to 0- less than 50mmHg} 0-6.66 {0-50 to 0-66.6 kPa to 0-500mmHg} 18 0-0.7 {0-5 to 0- less than 1.33 kPa to 0- less than 10mmHg} 0-1.33 {0-10 to 0- less than 9.3 kPa (*1) to 0- less than 70 nmHg} 25 0-35 {0-0.35 to 0- less than 68.6 kPa abs. to 0- less than 0.7 kgf/cm2} abs. 0-68.6 {0-0.7 to 0-686 kPa abs. to 0-7 kgf/cm2} [abs.] 26 0-10 {0-0.1 to 0- less than 19.6 kPa abs. to 0- less than 0.2 kgf/cm2} abs. 0-19.6 {0-0.2 to 0-196 kPa abs. to 0-2 kgf/cm2} [abs.] 27 0-3.4 {0-25 to 0- less than 6.66 kPa abs. to 0- less than 50mmHg} abs. 0-6.66 {0-50 to 0-66.6 kPa to 0-500mmHg} [abs.] 28 0-0.7 {0-5 to 0- less than 1.33 kPa abs. to 0- less than 10mmHg} abs. 0-1.33 {0-10 to 0- less than 9.3 kPa abs. (*2) to 0- less than 70 nmHg} [abs.] Transmission/Indication }1.0%FS/}1.5%FS }0.5%FS/}1.0%FS Note: *1) Transmitting accuracy : } 0.75%FS Indicating accuracy : } 1.25%FS *2) Transmitting accuracy : } 0.75%FS Indicating accuracy : } 1.25%FS Repeatability Within 0.3% FS Dead band Within 0.1% FS Indication Angle 44 degrees Scale length 150 mm Pointe Process variable ; Red Set-point value; Green Output indicator (40 mm) Scale range; 0 to 200 kPa {0 to 2 kgf/cm2}, Indicator accuracy; 3% FS Set-point Section Local setting Internal or external setting by setting knob Remote setting Pneumatic pressure setting of 20 to 100 kPa {0.2 to 1.0 kgf/cm2} Setting range 0 to 100% FS Controller Control action P + Manual reset, PI, PID, PD + Manual reset, PI + Batch, On-Off, Differential gap, P + External reset, PD + External reset Proportional band (P) 5-500% (direct or reverse action) Integral (I) 0.05 to 30 min. Derivative (D) 0.05 to 30 min. Differential gap 1 to 100% FS, adjustable Batch setting pressure 60 to 110 kPa {0.6 to 1.1 kgf/cm2}, adjustable External reset pressure 20 to 100 kPa {0.2 to 1.0 kgf/cm2} Manual reset 0 to 100% FS, adjustable (by pneumatic pressure setting.) General Specification Output 20 to 100 kPa {0.2 to 1.0 kgf/cm2}, 0 or Corresponding to supply air pressure (when on-off or differential gap control action) Minimum load I.D. 4 mm x 3 m + 20 cm3 Supply air pressure 140 } 14 kPa {1.4 } 0.14 kgf/cm2} Air consumption (50% output balanced) Indicating transmitter (A0) ; 5 L/min [N] Indicating controller (A1, A3) ; 9 Lmin [N] Indicating transmitting controller (A2, A4) ; 9 L/min [N] Manual controller (M) ; 3 L/min N] Saturated air supply capacity Transmitter output : 40 L/min [N] Controller Output ; 40 L/min [N] Manual control output ; 30 L/min [N] Air connection Rc . or . NPT internal thread Ambient temperature At meter body (process fluid) ; -40 to +120 ‹C At transmitter (ambient) ; -30 to +80 ‹C Relative humidity 10-90% RH Case, Door Enclosure ; Rain-tight and dust tight, meets JIS F 8001 class 3 splash-proof, NEMA 3, IEC IP 54 Materials ; Case........................................Aluminum die-cast Door ........................................ Polyester with fiberglass Door-glass...............................Reinforced glass (3 mm thick) Case finish ; Acryl baking finish (for corrosion-resistant and silver finish, refer to the optional specification.) Color of finish ; Dark beige (Munsell 10YR 4.7 / 0.5) Mounting Panel or 2 inch pipe mounting Weight Approx. 9.3 kg (model KFKB12-1412A1T-X) |