【DO!BOOK・ページリンク】
fi-06   27 / 46

BOOKをみる

10秒後にBOOKのページに移動します


No. SS2-KFD100-0100 -2 - SPECIFICATIONS Standard specification Item Specifications Detector Section Model No. Type of detector Measuring range (continuously adjustable) Process connection Pressure limit Overload protection Suppression (max.) Elevation (max.) 11 Standard type 0-25 to 0-500 kPa {0-2,500 to 50,000 mm H2O} Rc . or . NPT internal thread {center to center: 54 mm} -50 kPa to +10 MPa {-0.5 to 100 kgf/cm2} (PVC cover; -10 kPa to 1 MPa{-0.1 to 10 kgf/cm2}) To 10 MPa {100 kgf/cm2} in either direction. 500 kPa {50,000 mm H2O} 475 kPa {47,500 mm H2O} 22 0-2.5 to 0-53.9 kPa {0-250 to 5,500 mm H2O} 53.9 kPa {5,500 mm H2O} 51.4 kPa {5,250 mm H2O} 33 0-0.5 to 0-6 kPa {0-50 to 600 mm H2O} Rc . or . NPT internal thread (center to center: 54 mm, PVC cover : 71 mm) -50kPa to +3.5 MPa {0.5 to 35 kgf/cm2} (PVC cover; -10kPa to 1 MPa{-0.1 to 10 kgf/cm2} To 3.5 MPa {35 kgf/cm2} in either direction. 6 kPa {600 mm H2O} 5.5 kPa {550 mm H2O} 44 0-0.1 to 0-1.2 kPa {0-10 to 120 mm H2O} Rc . or . NPT internal thread (center to center: 54 mm) -1.5kPa to + 0.5 MPa {-150mm H2O to +5 kgf/cm2} To 0.5 MPa {5 kgf/cm2} in either direction. 1.2 kPa {120 mm H2O} 1.1 kPa {110 mm H2O} 61 Flange type 0-25 to 0-500 kPa {0-2,500 to 0-50,000 mm H2O} HP side: Flange Flush diaphragm type; 80 mm -JIS10K,30K(RF)equiv. flange 3 in. ANSI 150, 300(RF)equiv. flange Extended diaphragm type; 100 mm-JIS10K,30K(RF) equiv.flange 4 in.-ANSI150,300(RF) equiv.flange Length of extended part; 100 or 150 mm -50 kPa {-0.5 kgf/cm2} to maximum flange rated pressure. To maximum flange rated pressure in either direction. 500 kPa {50,000 mm H2O} 475 kPa {47,500 mm H2O} 62 0-2.5 to 0-53.9 kPa {0-250 to 0-5,500 mm H2O} LP side;Rc . or . NPT internal thread 53.9 kPa {5,500 mm H2O} 51.4 kPa {5,250 mm H2O} 71 Remote seal dia phragm type 0-25 to 0-500 kPa {0-2,500 to 0-50,000 mm H2O} Flange connection(both HP and LP side) Flush diaphragm type ; 80mm -JIS10K,30K(RF) equiv.flange 3 in.- ANSI 150, 300(RF) equiv. flange Extended diaphragm type; 100 mm -JIS10K,30K(RF) equiv.flange 4 in.-ANSI150,300(RF)equiv.flange Length of extended part; 100 or 150 mm -50 kPa {-0.5 kgf/cm2} to maximum flange rated pressure. To maximum flange rated pressure in either direction. 500 kPa {50,000 mm H2O} 475 kPa {47,500 mm H2O} 72 0-25 to 0-53.9 kPa {0-250 to 0-5,500 mm H2O} 53.9 kPa {5,500 mm H2O} 51.4 kPa {5,250 mm H2O} 81 High Sta - tic pressure type 0-25 to 0-500 kPa {0-2,500 to 0-50,000 mm H2O} .. Rc . or . NPT internal thread (center to center : 64 mm) .. When with manifold..… . in. socket welding (center to center : 110 mm) -50 kPa to +42 MPa {-0.5 to 420 kgf/cm2} 42 MPa {420 kgf/cm2} in either direction. 500 kPa {50,000 mm H2O} 475 kPa {47,500 mm H2O} 82 0-2.5 to 0-53.9 kPa {0-250 to 0-5,500 mm H2O} 53.9 kPa {5,500 mm H2O} 51.4 kPa {5,250 mm H2O} Note 1) Elevation + Span .. Maximum span, Suppression .. Maximum span. 2) Refer to the annexed table about Max. working pressure on Flange and remote seal type. PVC cover; -10 kPa to +1.5 Mpa {-0.1 to 15 kgf/cm2} or maximum flange rated pressure.