yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz
fi-06@@@36 / 46

BOOK‚š‚Ż‚é

10•bŒć‚ÉBOOK‚Ģƒy[ƒW‚ɈŚ“®‚µ‚Ü‚·


Azbil Corporation No. SS2-KFL100-0100 - 3 - Note) *1 The maximum temperature is available up to 200‹C. *2 If the optional code is gDh, it is not selectable carbon steel. Table 2 Material Model (temp. range) Parts U M A E D (350 to 400‹C) (200 to 350‹C) (0 to 200‹C) (0 to 200‹C) (-196 to 0‹C)*1 Torque tube Inconel Inconel Inconel SUS316L SUS316L Bonnet / Chamber Carbon steel (SFVC2A), SUS304, SUS316, SUS316L *2 Float SUS316L Bolts Chromium-molybdenum steel (SNB7) SUS304 Gasket Spiral type (semi-metallic, filler material: asbestos) Radiating fins Provided Non provided Table 3 Meter specification Item Specification Indicator section Indicating angle 44 deg. Scale length 150 mm Pointers PV: Red, SV: Green Output gauge Scale: 0 to 200 kPa, Indicating accuracy: } 3% F.S. Setting section Local setting Internal or external setting with a setting dial. Remote setting With pneumatic signal of 20 to 100 kPa Setting range 0 to 100% F.S. Controller section Control actions P + Manual reset, PI, PID, PD + Manual reset, PI + Batch, on-off, Differential gap, P + External reset, PD + External reset Proportional band (P) 5 to 500% (Direct or reverse action) Internal time (I) 0.05 to 30 min. Derivative time (D) 0.05 to 30 min. Differential gap 1 to 100% F.S., adjustable Batch setting pressure 60 to 110 kPa, adjustable External reset pressure 20 to 110 kPa, adjustable Manual reset pressure 0 to 100% F.S., adjustable (by pneumatic pressure setting) Standard specification Output 20 to 100 kPa, 0 or corresponding to supply air pressure (on-off, differential gap) Minimum load I.D. 4 mm ~ 3 m + 20 cm2 Supply air pressure 140 }14 kPa Air consumption (50% output balanced) Indicating transmitter: 5 ../min (N) Indication only: 5 ../min (N) Indicating controller: 5 ../min (N) Indication only: 5 ../min (N) Indicating transmitting and controller:9 ../min (N) Saturated air supply capacity Transmitter output: 40 ../min (N), Controller output: 40 ../min (N), Manual control output: 30 ../min (N) Air piping connections Rc1/4 (PT1/4 internal thread) or 1/4NPT internal thread Ambient temperature -30 to +80C, refer to Table 4. Relative humidity 10 to 90% RH Case and door Enclosure: Waterproof and dust tight, meets JIS F8001 class 3 splash-proof, NEMA3, IEC IP54 Material: Case ........... Diecast aluminum Door........... Polyester with fiberglass Door-glass . Reinforced glass (3 mm thick) Case finish: Baked acrylic finish (for corrosion-resistant or silver finish, refer to gOptional specificationsh) Color of finish: Dark beige (Munsell 10YR 4.7/0.5) 6 5