yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz
fi-06@@@40 / 46

BOOK‚ð‚Ý‚é

10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚·


Azbil Corporation No. SS2-KFL100-0100 - 7 - Note *1) Pressure rating g4h, gEh, gFh, gJh, and gKh cannot be selected for 5 inches/125 mm or the low density. *2) When other material is gDh .. Even 0-200‹C can be used. .. The element materials g1h cannot be selected. *3) The float material is as follows. Bolt/nut material is as follows. Note)* If Y131 is specified, bolt/nut material of the sign * is changeable to SUS304/SUS304. *4) Class900 is required consultation with our sales. Class1500 or more cannot be produced. *5) Please specify the float model number if reusing an existing Azbil Corporation float, model NQI, KFLB, KQP, or NQP. Please note the following: ..The selectable precondition as optional specification gCh for the existing product, gliquid level measurement specification: medium specific gravityh. Model number shall be NQI31.., NQI21.., KQP..1.., KFL..00-..1, NQP31.. or NQP21.. without Z. ..Note that the existing float diameter smaller than the standard specification ..Please confirm the dimensions of the existing float, and confirm the accuracy of measurement using the following formula. . Characteristics of the standard model KFLB Note) *This accuracy table is common for all KFLB models regardless of liquid level measurement, interface measurement or gravity measurement specifications. . Formula for checking accuracy (g) Where D: Float diameter (mm) H: Measuring range (float length, mm) ƒÁ: Specific gravity ƒÏstd: Standard density, ƒÏstd = 1 (g/cm3) ƒÎ: Circular constant . Reference: Formula for Genesis buoyant by float Where ƒÏ: Density of the ambient fluid (measuring fluid) V: Volume of the ambient fluid (measuring fluid) which the float displaced G: Gravitational acceleration Mf: Weight of the measuring fluid, which is displaced by the float *6) Please specify the existing chamber model number. However, the following attention is needed. The replaced model number must be without gZh of our model KQP..1.., KFL..00-..1, and NQP31.. and NQP21... if gZh included in the model number, the connection standard of the chamber and the bonnet are required ANSI / JPI 50, 300, 600 RF and the flange size (nominal size) is 3 inches respectively. Refer to the SLX series (No. SS2-SLX100-0100) for notes if the existing one is replace and modified. *7) Please fill in gZh on a basic model number end, and specified the range at the specific gravity measurement. *8) It is JIS and JPI (JPI 600 RTJ is excluded) is RF flange. *9) If included semi-standard specification (Y..) Please fill in the gYh sign on a basic model number end, and put Y number other. Please consult to our sales if required the combination of two Y spec. or more. *10)Specify option code g7h, if expand the measuring point of input output characteristics described to the test report from 3 points (0,50,100%) to 5 points (0,25,50,75,100%). Option code g7h cannot be specified alone. * Please specify the following when you order. ..Liquid name = ..Type of gas = ..Temperature Normal = ‹C MIN= ‹C Design temperature = ‹C ..Pressure Normal = MPa MAX= MPa Design pressure = MPa Other material code Float material U, M, A, E, D SUS316L Other material code Bolt/nut material U, M, A, E SNB7/S45C * D SUS304/SUS304 Weight gMfh of the measured fluid which is displaced by the float Mf > 400 400 > Mf > 200 200 > Mf Accuracy (%FS) }0.5 }1.0 Accuracy is not guaranteed .... ƒÎ . .. .... .. ƒÁ ƒÏ...... ...... ~ ~ ~ ~ ~ .. ........ ...... ƒÎ .... + ~ ~ ~ ~ ƒÁ ~ ƒÏ...... = ------------------------------------------------------------------------------------- .. = ƒÏ ~ .. ~ .. = .... ~ .. ..Model number KFLB.... - ........................- .. ..Specific gravity (fill in below the decimal point 3 digit.) For level meter = For boundary surface meter: Upper layer liquid = Lower layer liquid = For specific gravity meter: the range of the specific gravity of the measurement.= ..The dimension from the lower side of the bonnet flange to upper part of float (L1) = Round off below the decimal point, and fill it in by the unit of mm. Please consult to our sales separately for L1 > 1500 mm. : Specify, and fill in. 6 5