No. SS2-KFT100-0100 - 2 - SPECIFICATONS Standard Specifications Item Specifications Detector Section Measuring range Allowable over-range Maximum temperature plus 20% of span. Material Bulb : SUS304 Armored tube; SUS304 Capillary tube : SUS304 Pressure element : Phosphor bronze bellows Capillary tube length 5 m standard (6-9 m available in 1 m increments and 12 to 30 m in 2 m increments.) Function Indicating capacity ..1% FS Repeatability Within 0.3% FS Dead band Within 0.2% FS Indication Angle 44 degrees Scale length 150 mm Pointer Process variable ; Red, Set-point value ; Green Output indicator (.. 40 mm) Scale range; 0 to 200 kPa {0 to 2 kgf/cm2}, Indicator accuracy; ..3% FS Set-point Section Local setting Internal or external setting by setting knob. Remote setting Pneumatic pressure setting of 20 to 100 kPa {0.2 to 1.0 kgf/cm2} Setting range 0 to 100% FS Controller Control action P + Manual reset, PI, PID, PD + Manual reset, PI + Batch, On-Off, Differential gap, P + External reset, PD + External reset Proportional band (P) 5-500% (direct or reverse action) Integral (I) 0.05 to 30 min. Derivative (D) 0.05 to 30 min. Differential gap 1 to 100% FS, adjustable Batch setting pressure 60 to 110 kPa {0.6 to 1.1 kgf/cm2}, adjustable External reset pressure 20 to 100 kPa {0.2 to 1.0 kgf/cm2} Manual reset 0 to 100% FS, adjustable (by pneumatic pressure setting.) General Specifications Output 20 to 100 kPa {0.2 to 1.0 kgf/cm2}, 0 or Corresponding to supply air pressure (on-off, differential gap) Minimum load I.D. 4 mm x 3 m + 20 cm3 Supply air pressure 140 .. 14 kPa {1.4 .. 0.14 kgf/cm2} Air consumption (50% output balanced) Indicating transmitter (A0) ; 4 L/min [N] Indicating controller (A1, A3) ; 4 L/min [N] Indicating transmitting controller (A2, A4) ; 8 L/min [N] Manual controller (M) ; 3 L/min [N] Saturated air supply capacity Transmitter output ; 40 L/min [N] Controller output ; 40 L/min [N] Manual control output ; 30 L/min [N] Air connection Rc. or . NPT internal thread Ambient temperature -30 to 80 ..C (-30 to 60 ..C for 0 to 50 ..C range) Relative humidity 10 to 90% RH Case, Door Enclosure ; Rain-tight and dust-tight, meets JIS F 8001 class 3 splash-proof, NEMA 3, IEC IP54 Vibration resistant ................. Lloyd regulation or equivalent Materials ; Case ......................................Aluminum die-cast Door ......................................Polyester with fiberglass ; Door-glass ............................ Reinforced glass (3 mm thick) Case finish ; Acryl baking finish (for corrosion-resistant and silver finish, refer to the optional specification.) Color of finish ; Dark beige (Munsell 10YR 4.7/0.5) Mounting Panel, wall or 2 in. pipe mounting (mounting bolt, nut material; SUS304) Weight Approx. 6.7 kg (For pipe mounting type, local mode PI controller using 0 to 100 ..C element.) Special range : (..C) Special range (see note) : (..C) Span Range Span Range 50 0 to 50, 50 to 100 50 -20 to 30, 20 to 70 100 -50 to 50, 0 to 100, 100 to 200 60 -10 to 50 150 -50 to 100, 0 to 150 80 -15 to 65, 0 to 80 200 0 to 200, 100 to 300 100 50 to 150 300 0 to 300, 100 to 400 (*) 120 -20 to 100, 0 to 120 400 0 to 400 (*) 150 50 to 200 500 0 to 500 (*) 200 -50 to 150, 50 to 250 Note) * .....Gas-fill type (nitrogen) 250 -50 to 200, 0 to 250 Others ..... Liquid-fill type (kerosene) 300 -50 to 250 Note) Indicating accuracy: ..1.5% FS Repeatability : 1% FS |