yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-07@@@15 / 26 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
No. SS2-SLX100-0100 Azbil Corporation - 12 - Note) *1) For low specific gravity applications or 5B/125A, pressure ratings 4, E, F, J and K cannot be selected. *2) When other material is gDh, 1. Temperature 0 to 200 ‹C is available 2. Element material g1h cannot be selected. *3) Float materials are as follows: Bolt and nut materials are as follows: * If Y131 is specified bolt / nut material with * mark can be changed to SUS304 / SUS304 *4) For class 900, contact the Azbil Group representative. Also, class 1500 or higher cannot be manufactured. *5) For the NEPSI flameproof model, only the model codes with the Built-in Indicator are available. However, the codes with the elbow are not available. *6) When changing measurement point of input / output characteristic written on test report from 3 points (0, 50, 100 %) to 5 point (0, 25, 50, 75, 100 %), select g7h for option together. Option g7h cannot be selected by itself. *7) Specify when reusing Azbil Corporation's existing float. Pay attention to the following matters: 1. The prerequisites for selecting Additional Specifications C are: gLiquid level specifications - medium specific gravity - Azbil Corporation's models NQI31.., NQI21.., KQP..1.., KFL..00-..1, NQP31.. or NQP21.. without suffix Z 2. Small diameter float may be delivered due to special design outside of SS specification selection. 3. Please make sure that you confirm the diameter of the existing float to ensure accuracy. . Standard characteristics of model SLX * The model SLX offers consistent accuracy regardless of liquid level measurement, boundary surface measurement or hydrometer applications . Equation to calculate meter accuracy: . Wherein: D: Float diameter (mm) H: Measuring range (float length, mm) : Specific gravity std: Standard density, std. = 1 (g/cm3) : Circle ratio Reference: Equation to calculate buoyancy by float Whereas: : Density of surrounding (measured) fluid, V: Volume of surrounding (measured) fluid displaced by float, G: Gravity acceleration, Mf: Mass weight of fluid displaced by float *8) Specify when reusing a chamber. Pay particular attention to the following matters: Please ensure that the model number is one of the following Azbil Corporation's models: NQI31.., NQI21.., KQP..1.., KFL..00-..1, NQP31.. or NQP21.. without suffix gZh. If suffix gZh is specified, the chamber and bonnet connecting size should be 3 in. (nominal) ANSI/JPI50, 300, 600 RF. * When ordering, specify the following: Name of fluid = Type of gas = Temperature: Normal = ‹C Min. = ‹C Design temperature = ‹C Pressure: Normal = MPa Max = MPa Design pressure = MPa Other material Float material U, M, A, E, D SUS316L W Hastelloy C Other material Bolt / nut material U, M, A, E SNB7 / S45C * D, W SUS304 / SUS304 Mass of measured fluid displaced by float Mf Mf > 400 400 > Mf > 200 200 > Mf Accuracy +/- 0.5 +/- 1.0 Outside of guaranteed accuracy .... ƒÎ . .. .. .. .. ƒÁ ƒÏ...... .... ~ ~ ~ ~ ~ ... .. ........ .... ... ƒÎ .... + ~ ~ ~ ~ ƒÁ ~ ƒÏ...... = ----------------------------------------------------------------------------------------(.. ) Model SLX1..0-..................-......-.. Specific gravity (enter to third decimal point) For liquid level meter = For boundary surface measurement: Upper level liquid = Lower level liquid = For hydrometer: Range of specific gravity measurement = Dimension from the bottom of flange to top of float (L1) = Round off after the decimal point and specify using gmmh unit. If L1 > 1500 mm, consult with sales representative. : Make sure to specify the necessary information in the box. ƒÁ ƒÏ ƒÏ ƒÎ .. = ƒÏ ~ .. ~ .. = .... ~ .. ƒÏ |