MODEL SELECTION Multifunction pulse/Pneumatic Pressure Converter Model J - APN11 Multifunction Pulse/Pneumatic Pressure Converter (Model J - APN11) Model No. Structure : J - APN11 - (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14) - Optional Specifications Basic Model No. Multifunction Pulse/Pneumatic Pressure Converter Selections (1) 24V DC Isolation type B Pulse Length I Pulse Row J 0.2 to 1.0 kgf / cm2 1 3 to 15 psi 2 0.2 to 1.0 bar 3 20 to 100 kpa 4 4 to 20 mA DC 1 20 to 4 mA DC( (reverse characteristics) 2 R N (See Note 1) Standard 1 Corrosion - proof 2 (See Note 2) Heavy duty corrosion - proof 3 (See Note 2) Silver - painted 4 (See Note 2) Corrosion - proof silver - painted 5 (See Note 2) for 2 in. pipe T for wall S N/A X SUS304 (Packing diameter : 12) 1 (See Note 1) SUS304 (Packing diameter : 13) 2 (See Note 1) SUS304 (Packing diameter : 15) 3 (See Note 1) Plastics (Packing diameter : 15) 4 (See Note 1) N/A X Normally close H Normally open K N/A X Normally close H Normally open K N/A X One point (Upper), Normally close 1 One point (Lower), Normally close 2 Two points (Upper and lower), Normally close 3 (See Note 3&4) One point (Upper), Normally open 4 One point (Lower), Normally open 5 Two points (Upper and lower), Normally open 6 (See Note 3&4) (12) Water - resistant W Integrally mounted in the case 1 External 2 Contact Output available, Normally closed H (See Note 3) Contact Output available, Normally open K (See Note 3) Contact Output unavailable, Normally closed. E Options - N/A X Manual Operation Unit M (See Note 4) Pressure regulator with filter 7 Note 1 : Water - resistant gland unavailable for External Connection N. 2 : Additional price for Regulator with Air Filter selected is shown parenthesized. 3 : Two points pneumatic Pressure Output Signal Monitor unavailable with Limit Contact Output Signal available selected. 4 : Manual Operation Unit unavailable with Two points Pneumatic Pressure Output Signal Monitor Selected. Case (13) Power supply for P/I Unit (14) Limit Contact Signal (11) Pneumatic Pressure Output Signal Monitor (10) Pneumatic Pressure Failure Monitor (8) Water - resistant Gland (9) Power Failure Monitor (6) Case Finish (7) Mounting bracket (4) Current Signal (5) External Connection (2) Input Signal (3) Pneumatic Pressure Output Singnal Pneumatic Rc1/4, Electric G3/4 Internal thread Pneumatic 1/4 NPT, Electric G3/4 NPT Internal thread J - APN11 Power Supply Unit - 6 - No. SS2-APN100-0100 |