Effective reduction of CO2 at customers’ sites
We offer products, services, and solutions that help our customers reduce CO2 emissions at their sites. By FY2030, we aim to increase this effective reduction to 3.40 million metric tons of CO2. We strive to reduce society’s environmental impacts by providing automation equipment and systems for process optimization and stabilization, energy management, and other solutions to achieve a reduction in energy use and CO2 emissions by way of maintenance and services on those equipment and systems after delivery. We help to reduce environmental impacts throughout our customer’s product life cycles.
The total annual effective reduction of CO2 at customers’ sites in FY2024 was 2.72 million metric tons.*1 This is equivalent to about 1/375th of Japan’s CO2 emissions (about 1.02 billion metric tons).
This reduction impact would be equivalent to 2.85 million tons of CO2 if calculated using an electricity emission factor*2 based on the original assumption of 3.4 million tons of CO2. This represents approximately 89% of the initial reduction target of 3.2 million tons of CO2 for FY2024. Going forward, we will further refine the calculation methods, scope, and timeframe for existing businesses while strengthening reduction efforts. This includes thoroughly examining the reduction impact of expansion businesses and appropriately incorporating them to achieve our targets.
*1 To quantitatively assess the contribution to the reduction of environmental impact, the effects were grouped in the three categories of 1) effect of automation, 2) effect of energy management, and 3) effect of maintenance and services to theoretically estimate the difference between adopting and not adopting azbil Group products, services, and solutions at customers' sites. The global reduction impact is partially based on our original methods. An independent third party reviewed and validated the estimation methodology.
*2 Electricity emission factor for setting the 2030 target, which anticipated a roughly 10% improvement in the CO2 emission factor compared to the target setting period, based on the 2019 Basic Energy Plan.
Effective Reduction of CO2 at Customers' Sites
TOTAL 2.72 million metric tons of CO2/year
By Automation
We apply our measurement and control technologies to reduce environmental impact through our Building Automation, Advanced Automation, and Life Automation businesses.
Effective Reduction of CO2 at Customers' Sites
2.33 million metric tons of CO2/year
By BAS※1 and automated control in buildings
Estimation of CO2 reduction effects from actual figures for the previous 10-year period using the published specific energy consumption unit for each building type,based on total floor area.
※1 BAS:Building Automation Systems
By optimal control of processes in manufacturing facilities
The amount of CO2 reduction achieved by the implementation of optimum process control is calculated from the actual volume of CO2 reduction for the previous 10-year period, using published CO2 emissions data.
By Energy Management
The azbil Group contributes to reduced environmental impact through its ENEOPT™ energy management solutions for saving electricity, general energy conservation, and CO2 reduction.
Effective Reduction of CO2 at Customers' Sites
0.34 million metric tons of CO2/year
By ESCO※2 and other energy management solutions
Estimation of actual volume of CO2 reduction for the previous 10-year period for each building .(actual measured values before and after implementation of ESCO services)
※2 ESCO:Energy Service Company
By optimal and cooperative control of energy systems with optimization and visualization solutions
The amount of CO2 reduction achieved by the implementation of an energy conservation control system is estimated from the actual volume of CO2 reduction for the previous 10-year period, using published data or the actual CO2 emissions data before and after implementation.
By Maintenance and BuildingManagement Services
Leveraging the knowledge and expertise developed at customers’ sites in Japan and overseas, the azbil Group provides unique value-added services that help customers reduce their environmental impact.
Effective Reduction of CO2 at Customers' Sites
0.05 million metric tons of CO2/year
By comprehensive building management services
Estimation of CO2 reduction effects from actual figures using the published specific energy consumption unit for each building type, based on total floor area.
Click here for more information on the estimations.
By management of measurement and control instruments and systems in customers’ facilities
The CO2 reduction achieved by Optimum process control and energy conservation control system maintenance is estimated.
Click here for more information on the estimations.
Method of Estimating CO2 Reduction by a BAS and automated control in buildings
We estimated, on the basis of the following, the CO2 reduction for new and old buildings resulting from the introduction of a BAS and automatic control system.
- We estimated the reduced amount of CO2 emissions in 2024 resulting from Azbil Corporation products that were sold from 2014 to 2023.
- We also estimated the amount of CO2 reduction if no Azbil Corporation products or solutions were used at our customers’ sites.
- We used our system database to estimate the total floor area of sites and to categorize the use of the space.
- We used the energy consumption data (in MJ/m²/year) for each building usage type from the “Data-base for Energy Consumption of Commercial Building (DECC)” maintained by the Japan Sustainable Building Consortium (JSBC).
We converted the above energy consumption units into (kg-CO2/m²/year) using CO2 emission factors for electricity and heat (fuel).
In addition, we used fuel-electricity ratios of 6:4, 7:3, and 8:2 for hospitals and medical facilities, hotels, and others, respectively, based on data from the Energy Conservation Center, Japan. - We used the calorific value equivalents for electricity consumption and CO2 emission factors for heat that are specified by Japan’s energy conservation legislation. For energy weighting of buildings by area, and for CO2 emission factors for electricity, we used adjusted factors for electricity utilities that are released by the Ministry of Environment every year.
- We used energy consumption reduction rates from research entitled “Issuing Subsidies on Project Expense for Introduction of Highly Efficient Energy Systems into Dwelling/Building (Project on BEMS Introduction Support)” for 2006 to 2008.
- Estimation of our CO2 emission reduction in overseas markets uses figures for energy intensity that were set in consideration of the total floor space estimated from past installations, energy data for each country provided by the International Energy Agency, GDP, etc.
Method of Estimating CO2 Reduction by optimal control of processes in manufacturing facilities
The amount of CO2 reduction achieved by introducing optimum process control at production sites was estimated in the following way.
- The amount of CO2 emissions reduction in 2024 resulting from Azbil Corporation's products that were sold from 2014 to 2023 was estimated.
- The amount of CO2 reduction if no azbil Group products or solutions were used at our customers’ sites was estimated.
- CO2 reduction data provided by the Ministry of Economy, Trade and Industry was used.
- The energy consumption reduction rate was estimated from an estimate of the reduction achieved by the various supply systems.
* For facilities which have received Azbil’s maintenance (etc.) services, where continuing use is known, products sold in or before 2013 are also included in the estimate.
Method of Estimating CO2 Reduction by ESCO and other energy management solutions
We estimated the CO2 reduction achieved by energy conservation equipment and systems introduced by our ESCO service based on the following.
- We estimated the amount of reduced CO2 emissions in 2024 as a result of services implemented by our ESCO from 2014 to 2023.
- Estimates of CO2 reduction are based on the amount of reduction implemented by Azbil Corporation’s ESCO business and the amount of business eligible for subsidies contingent upon reduction of energy use.
- The CO2 reduction we helped to achieve overseas was estimated using the amount of electricity saved through our energy conservation projects and the emission coefficient for electricity, which was taken from International Energy Agency data.
Method of Estimating CO2 Reduction by optimal and cooperative control of energy systems with optimization and visualization solutions
The amount of CO2 reduction achieved by the introduction of optimum and cooperative energy control through optimization and visualization was estimated in the following way.
- The amount of CO2 emissions reduction in 2024 resulting from Azbil Corporation's products that were sold from 2014 to 2023 was estimated.
- The amount of CO2 reduction if no azbil Group products or solutions were used at our customers’ sites was estimated.
- The CO2 reduction achieved by the U-OPT total operational optimization package for utility facilities was estimated using data generated in feasibility studies before the introduction of the software.
- The amount of CO2 reduction achieved by optimum compressor capacity control was estimated, using data provided by the Energy Conservation Center, Japan, including the average amount of CO2 emissions per Type 1 Designated Energy Management Factory, and the average percentage and reduction rate in the amount of power used by compressors.
Method of Estimating CO2 Reduction by comprehensive building management services
We estimated the CO2 reduction achieved by comprehensive building management services for existing buildings based on the following.
- We estimated the CO2 reduction in 2024 by building maintenance management services.
- We also estimated the amount of CO2 reduction if no Azbil Corporation products or solutions were used at our customers’ sites.
- We used our system database to calculate the total floor area of sites and to categorize the use of the space.
- We used the energy consumption data (in MJ/m²/year) for each building usage type from the “Data-base for Energy Consumption of Commercial Building (DECC)” maintained by the Japan Sustainable Building Consortium (JSBC).
We converted the above energy consumption units into kg-CO2/m²/year using CO2 emission factors for electricity and heat (fuel).
In addition, we used fuel-electricity ratios of 6:4, 7:3, and 8:2 for hospitals and medical facilities, hotels, and others, respectively, based on data from the Energy Conservation Center, Japan. - We used the calorific value equivalents for electricity consumption and CO2 emission factors for heat that are specified by Japan’s energy conservation legislation. For energy weighting of buildings by area, and for CO2 emission factors for electricity, we used adjusted factors for electricity utilities that are released by the Ministry of Environment every year.
- The CO2 reduction rate is the actual value resulting from precise adjustment of the energy-saving controls that we installed at various remote maintenance service sites.
Method of Estimating CO2 Reduction by management of measurement and control
The amount of CO2 reduction achieved by the management of measurement and control devices and systems at production sites was estimated in the following way.
- The amount of CO2 emissions reduction in 2024 resulting from Azbil Corporation's products that were sold from 2014 to 2023 was estimated.
- The CO2 reduction achieved by maintenance in 2023 was estimated.
- The amount of CO2 reduction if no azbil Group products or solutions were used at our customers’ sites was estimated.